Marked Guidewire Technique Prevents Complications of Percutaneous Pedicle Screws and Precisely Controls Depth: Technical Note.

Li Xu, Zhang Wenzhi, Zhang Rui, Shang Xifu, Deng Chen, Kong Lei, Han Jintao

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We sought to describe a novel modified guidewire technique used in the placement of percutaneous pedicle screws (PPSs), which enables safe and precise control of the depth of screw placement and prevents excessive advancement of the guidewire with low radiation exposure. PPSs have been widely used and have many advantages. However, inadvertent advancement of the guidewire may damage peripheral tissue or viscera, and repeated confirmation of the depth of screw and guidewire leads to extensive radiation exposure.

METHODS

A modified guidewire with markers was used intraoperatively. The reading of the mark on the guidewire increased as the PPS advanced into the pedicle. The depth of the screw in the pedicle was calculated as the mark reading after each screw was rotated into the pedicle minus the initial mark reading. After all pedicle screws were placed, the positions of the screws were checked by C-arm or G-arm fluoroscopy.

RESULTS

The modified guidewire was applied in 41 thoracic-lumbar fracture patients. The depths of the percutaneous screws were precisely controlled as planned. There were no inadvertent breaches of the anterior cortices of the vertebrae. No patients reported neurologic symptoms, and there was no screw misplacement detected. Surgeons had no radiation exposure, and patients were only exposed once to the radiation.

CONCLUSIONS

The modified guidewire with markers is an effective device to precisely control the depth of PPSs and prevent complications of the guidewire in the placement of pedicle screws.

Для цитирования: Li Xu, Zhang Wenzhi, Zhang Rui, Shang Xifu, Deng Chen, Kong Lei, Han Jintao. Marked Guidewire Technique Prevents Complications of Percutaneous Pedicle Screws and Precisely Controls Depth: Technical Note.. World neurosurgery. 2018. DOI: 10.1016/j.wneu.2018.07.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.