MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/03635465221143385

Медицинская библиотека · The American journal of sports medicine · 2023

Challenging the Perceptions of Human Tendon Allografts: Influence of Donor Age, Sex, Height, and Tendon on Biomechanical Properties.

Ashton Dylan M, Blaker Carina L, Hartnell Nicholas, Haubruck Patrick, Hefferan Samantha A, Little Christopher B, Clarke Elizabeth C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The use of allograft tendons has increased for primary and revision anterior cruciate ligament reconstruction, but allograft supply is currently limited to a narrow range of tendons and donors up to the age of 65 years. Expanding the range of donors and tendons could help offset an increasing clinical demand.

PURPOSE: To investigate the effects of donor age, sex, height, and specific tendon on the mechanical properties of a range of human lower leg tendons.

STUDY

DESIGN

Descriptive laboratory study.

METHODS

Nine tendons were retrieved from 39 fresh-frozen human cadaveric lower legs (35 donors [13 female, 22 male]; age, 49-99 years; height, 57-85 inches [145-216 cm]) including: Achilles tendon, tibialis posterior and anterior, fibularis longus and brevis, flexor and extensor hallucis longus, plantaris, and flexor digitorum longus. Tendons underwent tensile loading to failure measuring cross-sectional area (CSA), maximum load, strain at failure, ultimate tensile strength, and elastic modulus. Results from 332 tendons were analyzed using mixed-effects linear regression, accounting for donor age, sex, height, and weight.

RESULTS

Mechanical properties were significantly different among tendons and were substantially greater than the effects of donor characteristics. Significant effects of donor sex, age, and height were limited to specific tendons: Achilles tendon, tibialis posterior, and tibialis anterior. All other tendons were unaffected. The Achilles tendon was most influenced by donor variables: greater CSA in men (β = 15.45 mm2; Šidák adjusted P < .0001), decreased maximum load with each year of increased age (β = -17.20 N per year; adjusted P = .0253), and increased CSA (β = 1.92 mm2 per inch; adjusted P < .0001) and maximum load (β = 86.40 N per inch; adjusted P < .0001) with each inch of increased height.

CONCLUSION

Mechanical properties vary significantly across different human tendons. The effects of donor age, sex, and height are relatively small, are limited to specific tendons, and affect different tendons uniquely. The findings indicate that age negatively affected only the Achilles tendon (maximum load) and challenge the exclusion of donors aged >65 years across all tendon grafts.

CLINICAL RELEVANCE: The findings support including a broader range of tendons for use as allografts for anterior cruciate ligament reconstruction and reviewing the current exclusion criterion of donors aged >65 years.

Для цитирования: Ashton Dylan M, Blaker Carina L, Hartnell Nicholas, Haubruck Patrick, Hefferan Samantha A, Little Christopher B, Clarke Elizabeth C. Challenging the Perceptions of Human Tendon Allografts: Influence of Donor Age, Sex, Height, and Tendon on Biomechanical Properties.. The American journal of sports medicine. 2023. DOI: 10.1177/03635465221143385.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.