MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2017.07.008

Медицинская библиотека · Contraception · 2017

Fast-track vs. delayed insertion of the levonorgestrel-releasing intrauterine system after early medical abortion - a randomized trial.

Korjamo Riina, Mentula Maarit, Heikinheimo Oskari

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To compare levonorgestrel (LNG) 52-mg intrauterine system (IUS) expulsion rates with fast-track (≤3 days) or delayed (2-4 weeks) insertion following mifepristone and misoprostol medical abortion.

STUDY

DESIGN

In this pilot trial, we randomized 108 women at ≤63 days' gestation to fast-track (n=55) or delayed (n=53) insertion. Follow-up visits occurred at 2-4 weeks, 3 months and 1 year. We assessed total and partial expulsion at 3 months and 1 year, adverse effects and bleeding profiles.

RESULTS

We had follow-up data at 3 months and 1 year for 41 (74.5%) and 37 (69.8%) women in the fast-track group and 31 (56.4%) and 28 (52.8%) women in the delayed group. By 3 months, expulsion occurred in six (12.5%) women after fast-track and one (2.3%) woman after delayed insertion [risk ratio (RR) 5.50, 95% confidence interval (CI) 0.69-43.90]; most (n=5) of these were partial expulsions in the fast-track group. By 1 year, expulsion had occurred in seven (14.6%) and five (11.5%) women in the fast-track and delayed groups, respectively (RR 1.28, 95% CI 0.44-3.75). We found no differences in rates of vacuum aspiration, residual tissue, infection and bleeding or bleeding patterns within 3 months of insertion.

CONCLUSION

Fast-track insertion of the LNG 52-mg IUS after medical abortion is feasible but may result in higher expulsion rates compared to delayed insertion. Due to lack of statistical power and high lost-to-follow-up rates, we were unable to fully address this question.

IMPLICATIONS: Fast-tract initiation of LNG 52-mg IUS contraception after medical abortion is feasible. It results in higher expulsion rates than delayed insertion but may improve postabortal intrauterine contraception uptake.

Для цитирования: Korjamo Riina, Mentula Maarit, Heikinheimo Oskari. Fast-track vs. delayed insertion of the levonorgestrel-releasing intrauterine system after early medical abortion - a randomized trial.. Contraception. 2017. DOI: 10.1016/j.contraception.2017.07.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.