DOI 10.1109/tbme.2010.2051225

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2010

Separation of heart sound signal from noise in joint cycle frequency-time-frequency domains based on fuzzy detection.

Tang Hong, Li Ting, Park Yongwan, Qiu Tianshuang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Noise is generally unavoidable during recordings of heart sound signal. Therefore, noise reduction is one of the important preprocesses in the analysis of heart sound signal. This was achieved in joint cycle frequency-time-frequency domains in this study. Heart sound signal was decomposed into components (called atoms) characterized by time delay, frequency, amplitude, time width, and phase. It was discovered that atoms of heart sound signal congregate in the joint domains. On the other hand, atoms of noise were dispersed. The atoms of heart sound signal could, therefore, be separated from the atoms of noise based on fuzzy detection. In a practical experiment, heart sound signal was successfully separated from lung sounds and disturbances due to chest motion. Computer simulations for various clinical heart sound signals were also used to evaluate the performance of the proposed noise reduction. It was shown that heart sound signal can be reconstructed from simulated complex noise (perhaps non-Gaussian, nonstationary, and colored). The proposed noise reduction can recover variations in the both waveform and time delay of heart sound signal during the reconstruction. Correlation coefficient and normalized residue were used to indicate the closeness of the reconstructed and noise-free heart sound signal. Correlation coefficient may exceed 0.90 and normalized residue may be around 0.10 in 0-dB noise environment, even if the phonocardiogram signal covers only ten cardiac cycles.

Для цитирования: Tang Hong, Li Ting, Park Yongwan, Qiu Tianshuang. Separation of heart sound signal from noise in joint cycle frequency-time-frequency domains based on fuzzy detection.. IEEE transactions on bio-medical engineering. 2010. DOI: 10.1109/tbme.2010.2051225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.