OBJECTIVE

To compare the efficacy of blind axillary vein puncture utilizing the new surface landmarks for the subclavian method.

METHODS

This prospective and randomized study was performed at two cardiology medical centers in East China. Five hundred thirty-eight patients indicated to undergo left-sided pacemaker or implantable cardioverter defibrillator implantation were enrolled, 272 patients under the axillary access and 266 patients under the subclavian approach. A new superficial landmark was used for the axillary venous approach, whereas conventional landmarks were used for the subclavian venous approach. We measured lead placement time and X-ray time from vein puncture until all leads were placed in superior vena cava. Meanwhile, the rate of success of lead placement and the type and incidence of complications were compared between the two groups.

RESULTS

There were no significant differences between the two groups in baseline characteristics or number of leads implanted. There were high success rates for both strategies (98.6% [494/501] vs. 98.4% [479/487], P=0.752) and similar complication rates (14% [38/272] vs. 15% [40/266], P=0.702). Six cases in the control group developed subclavian venous crush syndrome and five had pneumothorax, while neither pneumothorax nor subclavian venous crush syndrome was observed in the experimental group.

CONCLUSION

We have developed a new blind approach to cannulate the axillary vein, which is as effective as the subclavian access, safer than that, and also allows to get this vein without the guidance of fluoroscopy, contrast, or echography.

Для цитирования: Shi Yaming, Zong Yongzhong. The New Surface Landmarks for Blind Axillary Vein Puncture.. Brazilian journal of cardiovascular surgery. 2020. DOI: 10.21470/1678-9741-2019-0422.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.