OBJECTIVE

The purpose of this study is to determine which MRI parameters of fetal head and neck masses predict high-morbidity neonatal outcomes, including ex utero intrapartum treatment (EXIT) procedure.

MATERIALS AND

METHODS

This retrospective study (2004-2016) included parameters of polyhydramnios (based on largest vertical pocket), mass effect on the trachea, mass midline extension, and morphologic grade and size of masses. The morbid cohort included those requiring an EXIT procedure, difficult intubation at delivery, or lethal outcome. Predictive modeling with a multivariable logistic regression and ROC analysis was then performed.

RESULTS

Of 36 fetuses, five were delivered by EXIT procedures, there was one neonatal death within 12 hours after delivery, and another neonate required multiple intubation attempts. The remaining 29 fetuses were delivered at outside institutions with no interventions or neonatal morbidity. The largest vertical pocket and mass effect on the trachea were selected as independent predictors by the logistic regression. The cross-validated ROC AUC was 0.951 (95% CI, 0.8795-1).

CONCLUSION

The largest vertical pocket measurement and mass effect on the trachea were the most contributory MRI parameters that predicted significant morbidity in fetuses with masses of the face and neck, along with other significant parameters. These parameters predict significant morbid neonatal outcomes, including the need for EXIT procedures.

Для цитирования: Ng Timothy W, Xi Yin, Schindel David, Beavers Angela, Santiago-Munoz Patricia, Bailey April A, Twickler Diane M. Fetal Head and Neck Masses: MRI Prediction of Significant Morbidity.. AJR. American journal of roentgenology. 2018. DOI: 10.2214/ajr.18.19753.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.