MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00167-018-4926-2

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018

No neurovascular damage after creation of an accessory anteromedial portal for arthroscopic reduction and fixation of coronoid fractures.

Arrigoni Paolo, Cucchi Davide, Guerra Enrico, Luceri Francesco, Nicoletti Simone, Menon Alessandra, Randelli Pietro

СтатьяПеревод в очереди

Аннотация

PURPOSE: Arthroscopic reduction and internal fixation for coronoid process fractures has been proposed to overcome limitations of open approaches. Currently, arthroscopy is most frequently used to assist insertion of a retrograde guide wire for a retrograde cannulated screw. The present anatomical study presents an innovative arthroscopic technique to introduce an antegrade guide wire from an accessory anteromedial portal and evaluates its safety and reproducibility.

METHODS

Six fresh-frozen cadaver specimens were obtained and prepared to mimic an arthroscopic setting. The coronoid process was localized and a 0.9 mm Kirschner wire was introduced from an accessory anteromedial portal, located 2 cm proximal to the standard anteromedial portal. At the end of the procedure, a lateral radiograph was taken to verify the Kirschner wire position and open dissection was conducted to evaluate possible damage to neurovascular structures.

RESULTS

The Kirschner wire was drilled without complications in the coronoid process of all six specimens. Damage of the brachial artery, the median nerve, and the ulnar nerve did not occur in any specimen. A corridor between the brachialis muscle, the median intermuscular septum, and the pronator teres could be identified as suitable for the wire passage.

CONCLUSION

This study presents a safe and reproducible technique combining the possibility to introduce a guide wire from the anteromedial part of the coronoid, under direct visual control, with a completely arthroscopic approach. This wire can guide the introduction of a retrograde cannulated screw from the dorsolateral ulna to the tip of the coronoid. This new arthroscopic approach permits to obtain improved visual control over coronoid process fixation, without endangering neurovascular structures.

Для цитирования: Arrigoni Paolo, Cucchi Davide, Guerra Enrico, Luceri Francesco, Nicoletti Simone, Menon Alessandra, Randelli Pietro. No neurovascular damage after creation of an accessory anteromedial portal for arthroscopic reduction and fixation of coronoid fractures.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2018. DOI: 10.1007/s00167-018-4926-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.