MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e3181c11e5d

Медицинская библиотека · Cornea · 2010

Effect of incision width on graft survival and endothelial cell loss after Descemet stripping automated endothelial keratoplasty.

Price Marianne O, Bidros Maria, Gorovoy Mark, Price Francis W, Benetz Beth A, Menegay Harry J, Debanne Sara M, Lass Jonathan H

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the effect of incision width (5.0 and 3.2 mm) on graft survival and endothelial cell loss 6 months and 1 year after Descemet stripping automated endothelial keratoplasty (DSAEK).

METHODS

One hundred sixty-seven subjects with endothelial decompensation from a moderate-risk condition (principally Fuchs dystrophy or pseudophakic corneal edema) underwent DSAEK by 2 experienced surgeons. The donor was folded over and inserted with single-point fixation forceps. This retrospective analysis assessed graft survival, complications, and endothelial cell loss, which was calculated from baseline donor and 6-month and 1-year postoperative central endothelial images evaluated by an independent specular microscopy reading center.

RESULTS

No primary graft failures occurred in either group. One-year graft survival rates were comparable (98% vs 97%) in the 5.0- and 3.2-mm groups, respectively (P = 1.0). Complications included graft dislocation, graft rejection episodes, and elevated intraocular pressure and occurred at similar rates in both groups (P > or = 0.28). Pupillary block glaucoma did not occur in either group. Mean baseline donor endothelial cell density did not differ: 2782 cells per square millimeter in the 5.0-mm (n = 64) and 2784 cells per square millimeter in the 3.2-mm (n = 103) groups. Percent endothelial cell loss was 27% +/- 20% (n = 55) versus 40% +/- 22% (n = 71; 6 months) and 31% +/- 19% (n = 45) versus 44% +/- 22% (n = 62; 12 months) in the 5.0- and 3.2-mm incision groups, respectively (both P < 0.001).

CONCLUSIONS

One year after DSAEK, overall graft success was comparable for the 2 groups; however, the 5.0-mm incision width resulted in substantially lower endothelial cell loss at 6 and 12 months.

Для цитирования: Price Marianne O, Bidros Maria, Gorovoy Mark, Price Francis W, Benetz Beth A, Menegay Harry J, Debanne Sara M, Lass Jonathan H. Effect of incision width on graft survival and endothelial cell loss after Descemet stripping automated endothelial keratoplasty.. Cornea. 2010. DOI: 10.1097/ico.0b013e3181c11e5d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.