MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mcg.0000000000002013

Медицинская библиотека · Journal of clinical gastroenterology · 2025

Endoscopic Ultrasound-based Shear Wave Elastography for Detection of Advanced Liver Disease.

AbiMansour Jad, Chin Jerry Yung-Lun, Kaur Jyotroop, Vargas Eric J, Abu Dayyeh Barham K, Law Ryan, Garimella Vishal, Levy Michael J, Storm Andrew C, Dierkhising Ross, Allen Alina, Venkatesh Sudhakar, Chandrasekhara Vinay

СтатьяПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Endoscopic ultrasound shear wave elastography (EUS-SWE) is a novel modality for liver stiffness measurement. The aims of this study are to evaluate the performance and reliability of EUS-SWE for detecting advanced liver disease in a prospective cohort.

METHODS

EUS-SWE measurements were prospectively obtained from patients undergoing EUS between August 2020 and March 2023. Liver stiffness measurements were compared between patients with and without advanced liver disease (ALD), defined as stage ≥3, to determine diagnostic accuracy for advanced fibrosis and portal hypertension. Logistic regression was performed to identify variables that impact the reliability of EUS-SWE readings. Select patients underwent paired magnetic resonance elastography (MRE) for liver fibrosis correlation.

RESULTS

Patients with ALD demonstrated higher liver stiffness compared to healthy controls (left lobe: 17.6 vs. 12.7 kPa, P <0.001; median right lobe: 24.8 vs. 11.0 kPa, P <0.001). The area under the receiver operator characteristic (AUROC) for the detection of ALD was 0.73 and 0.80 for left and right lobe measurements, respectively. General anesthesia was associated with reliable EUS-SWE liver readings (odds ratio: 2.73, 95% CI: 1.07-7.39, P =0.040). Left lobe measurements correlated significantly with MRE with an increase of 0.11 kPa (95% CI: 0.05-0.17 kPA) for every 1 kPa increase on EUS-SWE. D.

CONCLUSIONS

SWE is a promising technology that can readily be incorporated into standard EUS examinations for the assessment of ALD.

Для цитирования: AbiMansour Jad, Chin Jerry Yung-Lun, Kaur Jyotroop, Vargas Eric J, Abu Dayyeh Barham K, Law Ryan, Garimella Vishal, Levy Michael J, Storm Andrew C, Dierkhising Ross, Allen Alina, Venkatesh Sudhakar, Chandrasekhara Vinay. Endoscopic Ultrasound-based Shear Wave Elastography for Detection of Advanced Liver Disease.. Journal of clinical gastroenterology. 2025. DOI: 10.1097/mcg.0000000000002013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.