← Поиск публикаций

DOI 10.1016/j.cjca.2019.12.003

Медицинская библиотека · The Canadian journal of cardiology · 2019

Noninvasive Microvascular Indices Reveal Peripheral Vascular Abnormalities in Patients With Suspected Coronary Microvascular Dysfunction.

Nardone Massimo, Miner Steven, McCarthy Mary, Ardern Chris I, Edgell Heather

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Reactive hyperemia peripheral arterial tonometry and flow-mediated dilation are common noninvasive measures of peripheral vascular function. However, their relationship with the coronary circulation, particularly in coronary microvascular dysfunction (CMD), is unclear. Therefore, the purpose of this study is to compare these noninvasive measurements with coronary microvascular function after endothelial-independent, endothelial-dependent, and sympathetically mediated pharmacologic hyperemia.

METHODS

Forty-seven patients with suspected CMD completed peripheral and coronary assessments. The reactive hyperemia index was collected using the EndoPAT2000 device, whereas a subset of patients (n = 28) completed brachial artery flow-mediated dilation using duplex ultrasound. Coronary microvascular function was quantified using the resistance and flow responses to intravenous adenosine (140 μg/kg/min), dobutamine (40 μg/kg/min), and intracoronary acetylcholine (100 μg). Abnormal coronary microvascular responses to adenosine and/or acetylcholine were used to define CMD.

RESULTS

The reactive hyperemia index (No CMD: 0.85 ± 0.23 vs CMD: 0.61 ± 0.26, P < 0.05) and flow-mediated dilation (No CMD: 7.2 ± 2.3 vs CMD: 4.8 ± 3.1; P < 0.05) were attenuated in patients with CMD. Whereas the reactive hyperemia index was correlated with the resistance and flow responses to dobutamine (ρ = -0.44 and ρ = 0.39, respectively; P < 0.05), flow-mediated dilation was correlated with the resistance responses to both adenosine (ρ = -0.48; P < 0.05) and acetylcholine (ρ = -0.66; P < 0.05). Lastly, the reactive hyperemia index and flow-mediated dilation had sensitivities of 80% and 69% and specificities of 71% and 93%, respectively, for identifying patients with CMD.

CONCLUSIONS

Peripheral vascular function is attenuated in CMD, and noninvasive measurements are associated with coronary responses to pharmaceutical stimulation.

Для цитирования: Nardone Massimo, Miner Steven, McCarthy Mary, Ardern Chris I, Edgell Heather. Noninvasive Microvascular Indices Reveal Peripheral Vascular Abnormalities in Patients With Suspected Coronary Microvascular Dysfunction.. The Canadian journal of cardiology. 2019. DOI: 10.1016/j.cjca.2019.12.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.