MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2022.08.013

Медицинская библиотека · American journal of ophthalmology · 2022

Baseline Microperimetry and OCT in the RUSH2A Study: Structure-Function Association and Correlation With Disease Severity.

Lad Eleonora M, Duncan Jacque L, Liang Wendi, Maguire Maureen G, Ayala Allison R, Audo Isabelle, Birch David G, Carroll Joseph, Cheetham Janet K, Durham Todd A, Fahim Abigail T, Loo Jessica, Deng Zengtian, Mukherjee Dibyendu, Heon Elise, Hufnagel Robert B, Guan Bin, Iannaccone Alessandro, Jaffe Glenn J, Kay Christine N, Michaelides Michel, Pennesi Mark E, Vincent Ajoy, Weng Christina Y, Farsiu Sina, Foundation Fighting Blindness Consortium Investigator Group

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To investigate baseline mesopic microperimetry (MP) and spectral domain optical coherence tomography (OCT) in the Rate of Progression in USH2A-related Retinal Degeneration (RUSH2A) study.

DESIGN

Natural history study

METHODS

Setting

16 clinical sites in Europe and North AmericaStudy Population: Participants with Usher syndrome type 2 (USH2) (N = 80) or autosomal recessive nonsyndromic RP (ARRP) (N = 47) associated with biallelic disease-causing sequence variants in USH2AObservation Procedures: General linear models were used to assess characteristics including disease duration, MP mean sensitivity and OCT intact ellipsoid zone (EZ) area. The associations between mean sensitivity and EZ area with other measures, including best corrected visual acuity (BCVA) and central subfield thickness (CST) within the central 1 mm, were assessed using Spearman correlation coefficients.

MAIN OUTCOME MEASURES: Mean sensitivity on MP; EZ area and CST on OCT.

RESULTS

All participants (N = 127) had OCT, while MP was obtained at selected sites (N = 93). Participants with Usher syndrome type 2 (USH2, N = 80) and nonsyndromic autosomal recessive Retinitis Pigmentosa (ARRP, N = 47) had the following similar measurements: EZ area (median (interquartile range [IQR]): 1.4 (0.4, 3.1) mm2 vs 2.3 (0.7, 5.7) mm2) and CST (median (IQR): 247 (223, 280) µm vs 261 (246, 288), and mean sensitivity (median (IQR): 3.5 (2.1, 8.4) dB vs 5.1 (2.9, 9.0) dB). Longer disease duration was associated with smaller EZ area (P < 0.001) and lower mean sensitivity (P = 0.01). Better BCVA, larger EZ area, and larger CST were correlated with greater mean sensitivity (r > 0.3 and P < 0.01). Better BCVA and larger CST were associated with larger EZ area (r > 0.6 and P < 0.001).

CONCLUSIONS

Longer disease duration correlated with more severe retinal structure and function abnormalities, and there were associations between MP and OCT metrics. Monitoring changes in retinal structure-function relationships during disease progression will provide important insights into disease mechanism in USH2A-related retinal degeneration.

Для цитирования: Lad Eleonora M, Duncan Jacque L, Liang Wendi, Maguire Maureen G, Ayala Allison R, Audo Isabelle, Birch David G, Carroll Joseph, Cheetham Janet K, Durham Todd A, Fahim Abigail T, Loo Jessica, Deng Zengtian, Mukherjee Dibyendu, Heon Elise, Hufnagel Robert B, Guan Bin, Iannaccone Alessandro, Jaffe Glenn J, Kay Christine N, Michaelides Michel, Pennesi Mark E, Vincent Ajoy, Weng Christina Y, Farsiu Sina, Foundation Fighting Blindness Consortium Investigator Group. Baseline Microperimetry and OCT in the RUSH2A Study: Structure-Function Association and Correlation With Disease Severity.. American journal of ophthalmology. 2022. DOI: 10.1016/j.ajo.2022.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.