DOI 10.1111/j.1755-3768.2009.01849.x
Comparison of bimanual and micro-coaxial phacoemulsification with torsional ultrasound.
Аннотация
PURPOSE: To evaluate the efficacy and postoperative outcomes of bimanual and micro-coaxial phacoemulsification with torsional ultrasound.
METHODS
In this prospective randomized series, eyes with age-related cataract were randomly divided into bimanual phacoemulsification and micro-coaxial phacoemulsification groups. Data included preoperative and postoperative corrected distance visual acuity (CDVA), central/temporal corneal thickness, endothelial cell density and intraoperative ultrasound time, cumulative dissipated energy and balanced salt solution volume.
RESULTS
The study evaluated 89 patients (89 eyes). When compared between micro-coaxial and bimanual phaco groups, ultrasound time (57 ± 24 second versus 85 ± 40 second, p < 0.01), cumulative dissipated energy (10 ± 7 versus 14 ± 7, p = 0.01) and balanced salt solution volume (55 ± 19 ml l versus 75 ± 20 ml, p < 0.01) were significantly lower in micro-coaxial phaco group. At 1 day, there were no statistically significant differences in CDVA (p = 0.68) or central corneal thickness (p = 0.48) between two groups; temporal corneal thickness was statistically significantly thicker in bimanual phaco group (1247 ± 123 μm) than that in micro-coaxial phaco group (1108 ± 131 μm, p = 0.01). There were no statistically significant differences in CDVA, central/temporal corneal thickness, or endothelial cell density between two groups 30 days postoperatively (all p values >0.05).
CONCLUSION
With rapid visual rehabilitation and comparable endothelial cell loss, both bimanual and micro-coaxial phacoemulsification procedures with torsional ultrasound are efficient for moderate nuclear cataract extraction.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.