Cost-utility of point-of-care viscoelastic hemostatic assays in the management of bleeding during cardiac surgery: A single-blinded prospective multicenter stepped wedge cluster randomized trial in French context.

Vourc'h Mickael, Boissier Elodie, Lakhal Karim, Grosjean Sandrine, Labaste François, Robin Emmanuel, Bougle Adrien, Mattei Mathieu, Morel Jérôme, Wurtz Véronique, Mertes Paul-Michel, Zlotnik Diane, Lagier David, Beurton Antoine, Rineau Emmanuel, Fischer Marc-Olivier, May Marc-Antoine, Médard Anne, Guimbretiere Guillaume, Durand-Zaleski Isabelle, Pere Morgane, Rozec Bertrand, Rigal Jean-Christophe

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The IMOTEC study aims to determine whether a point-of-care viscoelastic hemostatic assay (VHA)-guided algorithm is cost-effective for the management of ongoing bleeding.

METHODS

Stepped wedge cluster randomized trial, patient blinded, conducted at 16 French academic cardiac surgery centers from 01/2017 to 02/2020. Adults undergoing elective or urgent cardiac surgery with ongoing bleeding were enrolled during 2 successive inclusion periods: 1) transfusion guided on standard hemostasis tests (control period), and 2) transfusion using a VHA-guided algorithm. The primary objective was to estimate the efficiency of VHA based on the 1-year incremental cost-utility ratio (ICUR, primary outcome). Secondary outcomes included transfusion, postoperative complications, duration of stay in-hospital, reintervention, and mortality.

RESULTS

1095 patients were randomized, and 1044 (95.3%) were analyzed. The mean utility was 0.60 (±0.30) in the VHA vs. 0.61 (±0.30) in the control period, adjusted difference, -0.01 [95% CI, -0.09 to 0.07]. The ICUR did not suggest that the VHA-guided algorithm was cost-effective. One-year mortality was 12.0% for VHA and 10.9% for control, Hazard Ratio, 1.69 [95% CI, 0.98-2.89], P = .06. The frequency of plasma and platelet transfusions was significantly lower in the VHA compared to the control period (respectively, 48.8% vs. 72.4%, P < 0.0001 and 52.3% vs. 74.1%, P = .0002), whereas fibrinogen administration was more frequent in the VHA period (58.4% vs. 47.0%, P = .002). The median in-hospital length of stay was significantly shorter in the VHA vs. control period: 11.0 days (8.0-18.0) vs. 14.0 (9.0-22.0), P = .02.

CONCLUSIONS

The ICUR did not suggest that VHA was cost-effective in cardiac surgery patients with ongoing bleeding, compared with standard tests.

TRIAL REGISTRATION: Clinical trial submission: November 2, 2016 Registry name: Cost-Utility Analysis of Management of Peri Operative Hemorrhage Following Cardiac Surgery With Cardiopulmonary Bypass (IMOTEC) ClinicalTrials.gov Identifier: NCT02972684 URL registry: https://clinicaltrials.gov/study/NCT02972684.

Для цитирования: Vourc'h Mickael, Boissier Elodie, Lakhal Karim, Grosjean Sandrine, Labaste François, Robin Emmanuel, Bougle Adrien, Mattei Mathieu, Morel Jérôme, Wurtz Véronique, Mertes Paul-Michel, Zlotnik Diane, Lagier David, Beurton Antoine, Rineau Emmanuel, Fischer Marc-Olivier, May Marc-Antoine, Médard Anne, Guimbretiere Guillaume, Durand-Zaleski Isabelle, Pere Morgane, Rozec Bertrand, Rigal Jean-Christophe. Cost-utility of point-of-care viscoelastic hemostatic assays in the management of bleeding during cardiac surgery: A single-blinded prospective multicenter stepped wedge cluster randomized trial in French context.. Anaesthesia, critical care & pain medicine. 2025. DOI: 10.1016/j.accpm.2025.101704.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.