MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/micr.30318

Медицинская библиотека · Microsurgery · 2018

Laser doppler imaging as additional monitoring after digital replanting: A prospective study.

Schmid Marc, Seyed Jafari S Morteza, Haug Luzian, Surke Carsten, Hunger Robert E, Van De Ville Dimitri, Juon Personeni Bettina, Shafighi Maziar, Voegelin Esther

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Despite various exisiting monitoring methods, there is still a need for new technologies to improve the quality of post-operative evaluation of digital replantation. The purpose of the study is using a laser Doppler imaging device (Easy-LDI) as an additional tool to assess perfusion. In this method, the changes in the frequency of the laser ligth provide information regarding perfusion of the monitored tissue.

PATIENTS AND

METHODS

This study included seven patients (10 fingers; age of patients: 21-57 years) who suffered from a total (n = 6) or subtotal amputation (n = 4) due to accidents. In addition to hourly standard monitoring with clinical evaluation and skin thermometry, revascularized fingers were hourly monitored with Easy LDI for 48 h.

RESULTS

LDI measurement values ranged between 0.8 and 223 (mean 90.62 ± 21.42) arbitrary perfusion units (APU). The mean LDI values before and after revascularization were 7.1 ± 2.85 and 65.30 ± 30.83 APU, respectively. For the successful revascularized fingers (8 of 10 fingers) values from 19 to 223 APU (mean 98.52 ± 15.48) were demonstrated. All of the replants survived, but due to venous occlusion two digits required revision 12 and 35 h after revascularization, respectively. In the two cases, Easy-LDI also showed a constant and slow decline of the perfusion values. Furthermore, Pearson normalized correlation coefficient showed a positive significant correlation between temperatures of the replants and LDI-values (P < .001, r = +0.392) and a negative significant correlation between Δtemperature and LDI-values (P < .001, r = -0.474).

CONCLUSION

The LDI-device might be a promising additional monitoring technique in detection of perfusion disturbance in monitoring digital replantations.

Для цитирования: Schmid Marc, Seyed Jafari S Morteza, Haug Luzian, Surke Carsten, Hunger Robert E, Van De Ville Dimitri, Juon Personeni Bettina, Shafighi Maziar, Voegelin Esther. Laser doppler imaging as additional monitoring after digital replanting: A prospective study.. Microsurgery. 2018. DOI: 10.1002/micr.30318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.