m+Medelevator.RU
← Поиск публикаций
Fa yi xue za zhi · 2026

[Application of Automatic Magnetic Solid-Phase Extraction Instrument in Toxic Substances and Illegal Drugs].

Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xiao Yawen, Yang Yaoran, Yang Chongjun, Sun Yan, Chen Yue, Han Naihan, Meng Yuan, Wang Wenjun, Ren Qingshui, Zhu Jing, Zhang Tongshu, Wang Bing, Zhang Liyan

Аннотация

Magnetic solid-phase extraction (MSPE) serves as a key pretreatment technique for trace toxic substances and illegal drugs in complex matrices. Its degree of automation and extraction efficiency directly affect the sensitivity and reliability of analytical detection methods. At present, the detection of toxic substances and illegal drugs in forensic science continues to face challenges, including labor-intensive sample preparation, substantial matrix interference, limited enrichment efficiency, and difficulty in controlling operational variability. Conventional solid-phase extraction (SPE) techniques largely rely on manual procedures and are therefore unable to simultaneously meet the requirements for high throughput, accuracy and repeatability in trace analyte analysis. To address these limitations, our team established a novel MSPE method with high enrichment factors based on a self-developed fully automated MSPE instrument (Model HS-401-1). Combined with fluorescence immunoassay, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), and gas chromato- graphy-mass spectrometry (GC-MS), the proposed method was applied to the sample pretreatment and quantitative analysis of toxic substances and illegal drugs in wastewater, blood and urine matrices. The results demonstrated that the extraction instrument could accelerate sample pretreatment, markedly increase enrichment factors, effectively reduce matrix interference, and enhance the response signals of target analytes. The accuracy and precision of the established method met the requirements for trace-level analysis. Practical forensic identification cases verified that the automated MSPE system was able to reduce human-induced operational errors and greatly improve the degree of automation and overall efficiency of the pretreatment workflow. This instrument provides a reliable technical solution for the screening of toxic substances and illicit drugs in forensic science and demonstrates significant academic value as well as promising prospects for widespread application.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты