Distal locking screw length for volar locking plate fixation of distal radius fractures: Postoperative stability of full-length unicortical versus shorter screws.

Seki Y, Aoki T, Maehara H, Shirasawa S

СтатьяПеревод в очереди

Аннотация

We compared post-operative distal radius fracture (DRF) displacement after volar locking plate fixation using full-length unicortical and shorter-length distal locking screws. In this non-inferiority, retrospective cohort study, DRFs treated with volar locking plate fixation were evaluated on X-rays. In the full-length group, volar locking plate fixation was performed with full-length unicortical distal locking screws. In the shorter-length group, the distal locking screws were planned pre-operatively to be approximately 75% of the distal radius depth based on the lunate depth, and the same depth was drilled. Three radiographic parameters - ulnar variance, volar tilt, and radial inclination - were measured intra-operatively and at the final follow-up. The displacements were compared between the two groups. Each group contained 34 fractures. The mean ulnar variance between the two periods increased 1.1 mm in the full-length group and 1.3 mm in the shorter group (mean difference, 0.2 mm; 90% confidence interval, -0.3 to 0.6). The shorter group was not significantly inferior to the full-length one. Volar tilt increased 0.6° in the full-length group and -0.1° in the shorter group, while the radial inclination increased 0.1° in the full-length group and 0.2° in the shorter one. The differences in the increases were not significant. The post-operative DRF stability of 75%-length distal locking screws was not inferior to that of full-length unicortical screws. To prevent extensor pollicis longus tendon rupture, shorter distal locking screws and the same drilling depth may be preferable for volar locking plate fixation.

Для цитирования: Seki Y, Aoki T, Maehara H, Shirasawa S. Distal locking screw length for volar locking plate fixation of distal radius fractures: Postoperative stability of full-length unicortical versus shorter screws.. Hand surgery & rehabilitation. 2018. DOI: 10.1016/j.hansur.2018.10.246.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.