MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17219/dmp/193568

Медицинская библиотека · Dental and medical problems · 2026

Strain analysis in posterior implant-supported fixed dental prostheses - cemented compared to screwed: An in vitro study.

Naishlos Sarit, Nissan Joseph, Shely Asaf, Ben-Izhack Gil, Chaushu Liat, Rosner Ofir

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Research on the etiology of excessive strain at the implant neck, which may be associated with technical and biological complications, is still lacking.

OBJECTIVES

This in vitro study aimed to compare strain development at the implant neck between cementretained and screw-retained implant-supported fixed restorations, as well as among 3 prosthesis designs, using strain gauge analysis.

MATERIAL AND

METHODS

Six prosthetic configurations were fabricated and divided according to their retention mechanism: single crowns - cement-retained and screw-retained (SC-c and SC-s, respectively); splinted restorations - cement-retained and screw-retained (SP-c and SP-s, respectively); and simple threeunit bridges - cement-retained and screw-retained (SB-c and SB-s, respectively). Two strain gauges were attached to the implant necks. A vertical load of 200 N was applied simultaneously at 3 identical loading points on each restoration. Strain measurements were analyzed statistically using ANOVA and Scheffé's post hoc contrast analysis.

RESULTS

Cement-retained restorations transferred significantly less cervical strain to the implant neck than screw-retained restorations in all 3 prosthetic configurations tested (p < 0.001; SC-c < SC-s; SP-c < SP-s; and SB-c < SB-s). Single crowns transferred significantly less strain to the implant neck than the other restoration designs in both cement-retained and screw-retained groups (p < 0.001; SC-c < SP-c and SB-c; SC-s < SP-s and SB-s).

CONCLUSIONS

The use of cement-retained implant-supported fixed prostheses results in less strain development at the implant neck when subjected to high occlusal loads as compared to screw-retained prostheses. Splinting the adjacent implant-supported restorations does not necessarily reduce strain at the implant neck.

Для цитирования: Naishlos Sarit, Nissan Joseph, Shely Asaf, Ben-Izhack Gil, Chaushu Liat, Rosner Ofir. Strain analysis in posterior implant-supported fixed dental prostheses - cemented compared to screwed: An in vitro study.. Dental and medical problems. 2026. DOI: 10.17219/dmp/193568.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.