MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.100.5.1328

Медицинская библиотека · Chest · 1991

Ultrasound-guided pleural biopsy with Tru-Cut needle.

Chang D B, Yang P C, Luh K T, Kuo S H, Yu C J

СтатьяПеревод в очереди

Аннотация

We conducted a study of ultrasound (US)-guided pleural biopsy with a Tru-Cut needle and made a comparison with the results of a traditional pleural biopsy with an Abrams needle. A total of 49 patients with unilateral pleural effusion were included in this study. Twenty-four patients underwent a traditional pleural biopsy with an Abrams needle, and 25 patients underwent a US-guided pleural biopsy with a Tru-Cut needle. The age, sex, and underlying diseases in both groups were compatible. The amount of effusion was much less in the Tru-Cut group. In the patients who underwent the US-guided pleural biopsy with a Tru-Cut needle, the diagnostic sensitivity in pleural tuberculosis was 86 percent (6/7) and in pleural neoplasia it was 70 percent (7/10). In the patients who underwent traditional pleural biopsy with an Abrams needle, the diagnostic sensitivity in pleural tuberculosis was 20 percent (2/10) and in pleural neoplasia it was 44 percent (4/9). The result of US-guided pleural biopsy with a Tru-Cut needle was better than that of pleural biopsy with an Abrams needle, especially in pleural tuberculosis. No complication was found in the Tru-Cut group, but breakage and dislodgment of the tip of an Abrams needle occurred in one patient. The higher diagnostic yield in the Tru-Cut group may be attributed to the US guidance that can delineate the focal pleural abnormalities for biopsy. In conclusion, US-guided pleural biopsy by using a Tru-Cut needle was simple, safe, and well tolerated. It was particularly useful for patients with pleural tumor, thickened pleura, small amounts of pleural effusion, or loculated pleural effusion.

Для цитирования: Chang D B, Yang P C, Luh K T, Kuo S H, Yu C J. Ultrasound-guided pleural biopsy with Tru-Cut needle.. Chest. 1991. DOI: 10.1378/chest.100.5.1328.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.