MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1142/s2424835518500522

Медицинская библиотека · The journal of hand surgery Asian-Pacific volume · 2018

Screw Length Optimization of a Volar Locking Plate Using Three Dimensional Preoperative Planning in Distal Radius Fractures.

Totoki Yasukazu, Yoshii Yuichi, Kusakabe Takuya, Akita Kenichi, Ishii Tomoo

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

A three-dimensional (3D) digital pre-operative planning system for the osteosynthesis of distal radius fracture was developed. The objective of this study was to evaluate screw choices for three-dimensional (3D) digital pre-operative planning of osteosynthesis of distal radius fractures and to compare with the screw choices for the conventional method.

METHODS

Distal radius fracture patients who underwent osteosynthesis using volar locking plates were evaluated. Thirty wrists in the plan group utilized 3D preoperative planning, and nineteen wrists in the control group utilized conventional preoperative assessment. In the plan group, the 3D preoperative planning was performed prior to surgery. The reduction was simulated with 3D image, and the implant choice/placement also simulated on the 3D image. In the control group, standard preoperative planning was performed using posterior-anterior and lateral view radiographs, and CT scan. After the planning, osteosynthesis was performed. During the surgery, the operator performed the reduction and the placement of the plate while comparing images between the pre-operative plan and fluoroscopy. The distal screw lengths and the anteroposterior diameter of the radius along the axis of the distal screws were measured. The ratios of the screw length and radius diameter were evaluated. The screw/radius ratios within the range of 0.75-1.00 were considered appropriate. The screw choices less than 0.75, or greater than 1.00 were considered inappropriate. The rate of appropriate screw choices were compared between plan and control groups.

RESULTS

The results of appropriate screw choices were 86.1% and 74.8% in the plan group and the control group, respectively. The inappropriate screw choices were 14.0% and 25.2% in the plan group and the control group, respectively. The three-dimensional planning significantly increased appropriate screw choices compared to the conventional planning (p < 0.05).

CONCLUSIONS

Three-dimensional digital preoperative planning is useful for the optimization of screw lengths in osteosynthesis of distal radius fractures.

Для цитирования: Totoki Yasukazu, Yoshii Yuichi, Kusakabe Takuya, Akita Kenichi, Ishii Tomoo. Screw Length Optimization of a Volar Locking Plate Using Three Dimensional Preoperative Planning in Distal Radius Fractures.. The journal of hand surgery Asian-Pacific volume. 2018. DOI: 10.1142/s2424835518500522.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.