MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1164/ajrccm.165.5.2107059

Медицинская библиотека · American journal of respiratory and critical care medicine · 2002

Internet-based home monitoring of pulmonary function after lung transplantation.

Morlion Birgit, Knoop Christiane, Paiva Manuel, Estenne Marc

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Home monitoring of spirometry has been advocated in lung transplant recipients for the early detection of acute infection and rejection of the allograft. We have developed a user-friendly, Internet-based telemonitoring system providing direct transmission of home spirometry to the hospital. In this prospective study, we assessed patient adherence with the monitoring, agreement between home and hospital spirometry, intrasubject coefficient of variation (CV) for FEV(1) and FEF(25-75), and sensitivity of these variables for the detection of acute complications. Twenty-two bilateral-lung and heart-lung transplant recipients were followed for a median of 473 d (range, 60-822), during which 13,833 measurements were obtained. Patient compliance was 55% for two measurements a day and 84% for one measurement a day. Agreement between home and hospital spirometry was within 4% for FEV(1) and 6% for FEF(25-75). Mean CV was 3.2% for FEV(1) and 7.5% for FEF(25-75). Using transbronchial lung biopsy and/or bronchoalveolar lavage as gold standards, the sensitivity of home spirometry was 63%, and 23% of true positives were detected by changes in FEF(25-75) alone. We conclude that home monitoring of pulmonary function in lung transplant recipients via the Internet is feasible and provides very reproducible data; yet it has only a mild sensitivity for the detection of acute allograft dysfunction.

Для цитирования: Morlion Birgit, Knoop Christiane, Paiva Manuel, Estenne Marc. Internet-based home monitoring of pulmonary function after lung transplantation.. American journal of respiratory and critical care medicine. 2002. DOI: 10.1164/ajrccm.165.5.2107059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.