MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jns.2020.117142

Медицинская библиотека · Journal of the neurological sciences · 2020

Mechanical thrombectomy in acute ischemic stroke patients with left ventricular assist device.

Kitano Takaya, Sakaguchi Manabu, Yamagami Hiroshi, Ishikawa Tatsuya, Ishibashi-Ueda Hatsue, Tanaka Kanta, Okazaki Shuhei, Sasaki Tsutomu, Kadono Yoshinori, Takagaki Masatoshi, Nishida Takeo, Nakamura Hajime, Yanase Masanobu, Fukushima Norihide, Shiozawa Masayuki, Toyoda Kazunori, Takahashi Jun C, Funatsu Takayuki, Ryu Bikei, Yoshioka Daisuke, Toda Koichi, Murayama Shigeo, Kawamata Takakazu, Kishima Haruhiko, Sawa Yoshiki, Mochizuki Hideki, Todo Kenichi

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

As the number of patients with left ventricular assist device (LVAD) implantation has been increasing, treatment of LVAD-related ischemic stroke is becoming a critical issue. We sought to clarify the features of mechanical thrombectomy in LVAD-related stroke with large vessel occlusion.

METHODS

In a multi-center, retrospective case-control study, we compared 20 LVAD-related strokes with 33 non-LVAD strokes, all of which had large vessel occlusion in the anterior circulation treated with mechanical thrombectomy. A comparative histopathological examination of the retrieved thrombi was also performed.

RESULTS

Successful reperfusion was achieved in 75% of the LVAD-related strokes. The time from onset to reperfusion was similar to that of non-LVAD strokes, but the total number of device passes required for reperfusion (median, 2.5 versus 1, P = 0.01) and the incidences of post-procedural parenchymal and subarachnoid hemorrhage (25% versus 3%, P = 0.02 and 55% versus 15%, P = 0.01, respectively) were higher in LVAD-related strokes. Symptomatic intracranial hemorrhage occurred in 4 patients (20%) with LVAD-related strokes. The histopathological analysis revealed that the ratio of erythrocyte components was significantly lower in thrombi retrieved from patients with LVAD-related stroke than in those with non-LVAD stroke (19 ± 6% versus 41 ± 17%, P = 0.01).

CONCLUSIONS

Mechanical thrombectomy is feasible in patients with LVAD-related stroke. However, repetitive device passes are needed to achieve successful reperfusion mainly because of the structurally organized thrombi, and the higher risk of hemorrhagic complications should be considered, while offering this therapeutic alternative.

Для цитирования: Kitano Takaya, Sakaguchi Manabu, Yamagami Hiroshi, Ishikawa Tatsuya, Ishibashi-Ueda Hatsue, Tanaka Kanta, Okazaki Shuhei, Sasaki Tsutomu, Kadono Yoshinori, Takagaki Masatoshi, Nishida Takeo, Nakamura Hajime, Yanase Masanobu, Fukushima Norihide, Shiozawa Masayuki, Toyoda Kazunori, Takahashi Jun C, Funatsu Takayuki, Ryu Bikei, Yoshioka Daisuke, Toda Koichi, Murayama Shigeo, Kawamata Takakazu, Kishima Haruhiko, Sawa Yoshiki, Mochizuki Hideki, Todo Kenichi. Mechanical thrombectomy in acute ischemic stroke patients with left ventricular assist device.. Journal of the neurological sciences. 2020. DOI: 10.1016/j.jns.2020.117142.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.