MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2012.05.001

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2012

Biomechanical effect of rotator cuff augmentation with an acellular dermal matrix graft: a cadaver study.

Omae Hiromichi, Steinmann Scott P, Zhao Chunfeng, Zobitz Mark E, Wongtriratanachai Prasit, Sperling John W, An Kai-Nan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Acellular human dermal matrix grafts (Graftjacket; Wright Medical Technology, Arlington, TN, USA) are used clinically for rotator cuff augmentation without a detailed understanding of their biomechanical effects. The purpose of this study was to evaluate the effect of augmentation with dermal grafts on the biomechanical effects of rotator cuff repairs.

METHODS

Nine matched pairs of human cadaveric shoulders were used. A single-row rotator cuff repair combined with an augmentation graft was performed on one shoulder, and a single-row repair was performed on the contralateral shoulder as a control. An acellular dermal matrix graft was sutured to the tendon medially and fixed to the humerus laterally. The constructs were preloaded at 10 N and then cyclically loaded between 10 and 180 N for 1000 cycles, followed by tensile testing to failure at 1.0 mm/s.

FINDINGS: The maximum load of the augmentation group (560.2 N, SD 95.5) was greater than that of the control group (345.7 N, SD 60.8), while the linear stiffness of the augmentation group (65.2 N/mm, SD 15.6) was less than that of the control group (77.2 N/mm, SD 15.7). Reliable gap distance data were not obtained during cyclic loading in 5 of 9 augmented repairs due to the elasticity of the dermal matrix graft.

INTERPRETATION: The dermal matrix graft augmentation increased the maximum load but did not increase the linear stiffness. The elasticity of the dermal matrix graft affected the biomechanical effects of the augmented rotator cuff repairs.

Для цитирования: Omae Hiromichi, Steinmann Scott P, Zhao Chunfeng, Zobitz Mark E, Wongtriratanachai Prasit, Sperling John W, An Kai-Nan. Biomechanical effect of rotator cuff augmentation with an acellular dermal matrix graft: a cadaver study.. Clinical biomechanics (Bristol, Avon). 2012. DOI: 10.1016/j.clinbiomech.2012.05.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.