m+Medelevator.RU
← Поиск публикаций
Chest · 2002

Lung deposition of hydrofluoroalkane-134a beclomethasone is greater than that of chlorofluorocarbon fluticasone and chlorofluorocarbon beclomethasone : a cross-over study in healthy volunteers.

Клиническое исследованиеКлиническое исследование I фазыСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leach Chet L, Davidson Patricia J, Hasselquist Bruce E, Boudreau Robert J

Аннотация

STUDY OBJECTIVES: To compare the lung deposition of radiolabeled hydrofluoroalkane-134a beclomethasone dipropionate (HFA-BDP) with chlorofluorocarbon fluticasone propionate (CFC-FP) and chlorofluorocarbon beclomethasone (CFC-BDP).

DESIGN: Six-day, open-label, nonrandomized, crossover study.

SETTING: Clinical research laboratory.

PARTICIPANTS: Nine healthy, nonsmoking, adult volunteers.

INTERVENTIONS: On each study day, participants inhaled one or two puffs of 99mTc-labeled HFA-BDP, CFC-FP, or CFC-BDP. All products delivered 50 micro g per puff ex-valve. Subjects used a respiratory training and monitoring device to meet predefined, standardized inhalation patterns. Immediately after inhalation of radiolabeled study drug, planar gamma camera images were obtained.

MEASUREMENTS AND RESULTS: Radiolabeled HFA-BDP had a higher deposition in the lungs (53% ex-actuator) compared with CFC-FP (12 to 13%) and CFC-BDP (4%). Conversely, CFC-FP and CFC-BDP had a much higher distribution to the oropharynx (72 to 78%, and 82%, respectively) than HFA-BDP (29%). HFA-BDP was deposited evenly throughout the lungs, while CFC-FP and CFC-BDP deposition was primarily in the large central and intermediate airways. Andersen particle size sampling gave mass median aerodynamic diameters for HFA-BDP, CFC-FP, and CFC-BDP of 0.9 micro m, 2.0 micro m, and 3.5 micro m, respectively.

CONCLUSIONS: Lung deposition was greater with HFA-BDP compared with CFC-FP and CFC-BDP. Deposition values appeared to be related to the particle size distribution of each inhaler, with the smaller particles of HFA-BDP providing the greatest lung deposition and least oropharyngeal deposition.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты