MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0736-0266(01)00136-x

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2002

Low-intensity pulsed ultrasound increases the fracture callus strength in diabetic BB Wistar rats but does not affect cellular proliferation.

Gebauer Gregory P, Lin Sheldon S, Beam Heather A, Vieira Pedro, Parsons J Russell

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Type I diabetes mellitus (DM) is associated with impaired fracture healing. Specifically, DM affects multiple phases of fracture healing including early cellular proliferation and late phases resulting in inferior biomechanical properties. Recent studies demonstrated the utility of pulsed low-intensity ultrasound (US) to facilitate fracture healing. The current study evaluated the effects of daily application of US on mid-diaphyseal femoral fractures in DM and non-DM BB Wistar rats. Immunohistochemical staining for PCNA was used to evaluate cellular proliferation at 2, 4, and 7 days post-fracture. In concordance with previous findings. DM fracture callus demonstrated decreased cellular proliferation. Importantly, the application of US did not significantly alter the proliferation in either DM or control groups. However, mechanical testing revealed significantly greater torque to failure and stiffness in US-treated DM versus non-US-treated DM groups at six weeks post-fracture. Despite the inability of US to affect the early proliferative phase of fracture healing, its application clearly results in improved mechanical properties during the late phases of healing. These findings suggest a potential role of US as an adjunct for DM fracture treatment.

Для цитирования: Gebauer Gregory P, Lin Sheldon S, Beam Heather A, Vieira Pedro, Parsons J Russell. Low-intensity pulsed ultrasound increases the fracture callus strength in diabetic BB Wistar rats but does not affect cellular proliferation.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2002. DOI: 10.1016/s0736-0266(01)00136-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.