Highly selective and sensitive online measurement of trace exhaled HCN by acetone-assisted negative photoionization time-of-flight mass spectrometry with in-source CID.
Аннотация
Exhaled hydrogen cyanide (HCN) has been extensively investigated as a promising biomarker of the presence of Pseudomonas aeruginosa in the airways of patients with cystic fibrosis (CF) disease. Its concentration profile for exhalation can provide useful information for medical disease diagnosis and therapeutic procedures. However, the complexity of breath gas, like high humidity, carbon dioxide (CO2) and trace organic compounds, usually leads to quantitative error, poor selectivity and sensitivity for HCN with some of existing analytical techniques. In this work, acetone-assisted negative photoionization (AANP) based on a vacuum ultraviolet (VUV) lamp with a time-of- flight mass spectrometer (AANP-TOFMS) was firstly proposed for online measurement of trace HCN in human breath. In-source collision-induced dissociation (CID) was adopted for sensitivity improvement and the signal response of the characteristic ion CN- (m/z 26) was improved by about 24-fold. For accurate and reliable analysis of the exhaled HCN, matrix influences in the human breath including humidity and CO2 were investigated, respectively. A Nafion tube was used for online dehumidification of breath samples. Matrix-adapted calibration in the concentration range of 0.5-50 ppbv with satisfactory dynamic linearity and repeatability was obtained. The limit of quantitation (LOQ) for HCN at 0.5 ppbv was achieved in the presence of 100% relative humidity and 4% CO2. Finally, the method was successfully applied for online determination of human mouth- and nose-exhaled HCN, and the nose-exhaled HCN were proved to be reliable for assessing systemic HCN levels for individuals. The results are encouraging and highlight the potential of AANP-TOFMS with in-source CID as a selective, accurate, sensitive and noninvasive technique for determination of the exhaled HCN for CF clinical diagnosis and HCN poisoning assessment.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.