MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Kobe journal of medical sciences · 2019

Spinal Muscular Atrophy: Advanced Version of Screening System with Real-Time mCOP-PCR and PCR-RFLP for SMN1 Deletion.

Niba Emma Tabe Eko, Rochmah Mawaddah Ar, Harahap Nur Imma Fatimah, Awano Hiroyuki, Morioka Ichiro, Iijima Kazumoto, Takeshima Yasuhiro, Saito Toshio, Saito Kayoko, Takeuchi Atsuko, Lai Poh San, Bouike Yoshihiro, Matsuo Masafumi, Nishio Hisahide, Shinohara Masakazu

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Spinal Muscular Atrophy (SMA) is a common autosomal recessive neuromuscular disease characterized by defects of lower motor neurons. More than 95% of SMA patients show homozygous deletion for the survival motor neuron 1 (SMN1) gene. For the screening of SMN1 deletion using dried blood spot (DBS), we developed a new combined system with real-time "modified competitive oligonucleotide priming"-polymerase chain reaction (mCOP-PCR) and PCR restriction fragment length polymorphism (PCR-RFLP). Although our real-time mCOP-PCR method is secured enough to be gene-specific, its amplification efficiency is not as good because the reverse primers carry a nucleotide mismatched with the sequence of the pre-amplified product. The mismatch has consequently been generated in the process of introducing a restriction enzyme site in the pre-amplified products for PCR-RFLP.

METHOD: DBS samples of the subjects were stored at room temperature for a period of less than one year. Each subject had already been genotyped by the first PCR-RFLP using fresh blood DNA. SMN1/SMN2 exon 7 was collectively amplified using conventional PCR (targeted pre-amplification). Pre-amplified products were used as template in the real-time mCOP-PCR, and, on the other hand, were digested with DraI enzyme (PCR-RFLP). To improve the amplification efficiency of mCOP-PCR, one nucleotide change was introduced in the original reverse primers (SMN1-COP and SMN2-COP) to eliminate the mismatched nucleotide.

RESULTS

The real-time mCOP-PCR with a new primer (SMN1-COP-DRA or SMN2-COP-DRA) more rapidly and specifically amplified SMN1 and SMN2, and clearly demonstrated SMN1 deletion in an SMA patient. With the new primers, the amplification efficiencies of real-time mCOP-PCR were improved and the Cq values of SMN1 (+) and SMN2 (+) samples were significantly lowered.

CONCLUSION

In the advanced version of our screening system for homozygous SMN1 deletion using DBS, the real-time mCOP-PCR with newly-designed reverse primers demonstrated the presence or absence of SMN1 and SMN2 within a shorter time, and the results were easily tested by PCR-RFLP. This rapid and accurate screening system will be useful for detection of newborn infants with SMA.

Для цитирования: Niba Emma Tabe Eko, Rochmah Mawaddah Ar, Harahap Nur Imma Fatimah, Awano Hiroyuki, Morioka Ichiro, Iijima Kazumoto, Takeshima Yasuhiro, Saito Toshio, Saito Kayoko, Takeuchi Atsuko, Lai Poh San, Bouike Yoshihiro, Matsuo Masafumi, Nishio Hisahide, Shinohara Masakazu. Spinal Muscular Atrophy: Advanced Version of Screening System with Real-Time mCOP-PCR and PCR-RFLP for SMN1 Deletion.. The Kobe journal of medical sciences. 2019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.