m+Medelevator.RU
← Поиск публикаций
Mikrochimica acta · 2021

Magnetic dispersive solid-phase extraction of triazole and triazine pesticides from vegetable samples using a hydrophilic-lipophilic sorbent based on maltodextrin- and β-cyclodextrin-functionalized graphene oxide.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Majd Mahshid, Nojavan Saeed

Аннотация

Maltodextrin- and β-cyclodextrin-functionalized magnetic graphene oxide (mGO/β-CD/MD), a novel hydrophilic-lipophilic composite, was successfully fabricated and used for the co-extraction of triazines and triazoles from vegetable samples before HPLC-UV analysis. mGO/β-CD/MD was synthesized by chemical bonding of β-CD and MD to the surface of mGO, using epichlorohydrin (ECH) as a linker. The successful synthesis of mGO/β-CD/MD was confirmed by characterization tests, including attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), vibrating sample magnetometry (VSM), thermogravimetric analysis (TGA), energy-dispersive X-ray spectroscopy (EDX), Brunauer-Emmett-Teller (BET), and Barrett-Joyner-Halenda (BJH) analyses. The hydrophobic cavity of β-CD and a large number of hydroxyl groups on the MD structure contributed to the co-extraction of mentioned pesticides with a wide range of polarity. Under the optimized condition (sorbent amount, 30 mg; desorption time, 10 min; desorption solvent volume, 300 μL; desorption solvent, methanol/acetonitrile (1:1) containing 5% (v/v) acetic acid; extraction time, 20 min; and pH of sample solution, 7.0), good linearity within the range 1.0-1000 μg L-1 (r2 ≥ 0.992) was achieved. Extraction efficiencies were in the range 66.4-95.3%, and the limits of detection were 0.01-0.08 μg L-1. Relative recoveries for spiked samples were obtained in the range 88.4-112.0%, indicating that the matrix effect was insignificant, and good precisions (intra- and inter-day) were also achieved (RSDs < 9.0%, n = 3). The results confirmed that the developed method was efficient for the determination  of trace amounts of pesticides in potato, tomato, and corn samples.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты