Quantification of dynamic changes to blood volume and vascular flow in the primate corpus luteum during the menstrual cycle.
Аннотация
BACKGROUND
The objective of the current study was to determine changes to vascular parameters of nonhuman primate dominant ovarian structures by dynamic contrast-enhanced ultrasound (DCE-US).
MATERIALS AND
METHODS
Dynamic contrast-enhanced ultrasound with intravenous microbubble infusion was performed on the rhesus macaque ovary bearing the pre-ovulatory follicle and corpus luteum (CL) sequentially during the natural luteal phase (n = 8) and GnRH antagonist (antide)-induced luteal regression (n = 6).
RESULTS
Changes in luteal blood volume (BV) and vascular flow (VF) were observed between stages of the luteal phase Luteal BV was highest in early stage CL, before decreasing 2.5-fold in late stage CL (P < 0.06); in contrast, luteal VF peaked at mid luteal stage (P < 0.01). Two females identified with luteal insufficiency trended toward lower peak BV, compared to typical CLs. Another female was identified with a luteal cyst on the contralateral ovary, and a CL that regressed before P levels declined. After 72 hours of antide exposure, BV was reduced 2.3-fold (P = 0.03).
CONCLUSIONS
DCE-US provides a sensitive, non-invasive measurement of the dynamics of blood volume and flow in dominant ovarian structures.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.