Machine Learning-Based Analysis of Optical Coherence Tomography Angiography Images for Age-Related Macular Degeneration.

Alfahaid Abdullah, Morris Tim, Cootes Tim, Keane Pearse A, Khalid Hagar, Pontikos Nikolas, Alharbi Fatemah, Alalwany Easa, Almars Abdulqader M, Aldweesh Amjad, ALMansour Abdullah G M, Sergouniotis Panagiotis I, Balaskas Konstantinos

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Age-related macular degeneration (AMD) is the leading cause of visual impairment among the elderly. Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality that enables detailed visualisation of retinal vascular layers. However, clinical assessment of OCTA images is often challenging due to high data volume, pattern variability, and subtle abnormalities. This study aimed to develop automated algorithms to detect and quantify AMD in OCTA images, thereby reducing ophthalmologists' workload and enhancing diagnostic accuracy.

Methods

Two texture-based algorithms were developed to classify OCTA images without relying on segmentation. The first algorithm used whole local texture features, while the second applied principal component analysis (PCA) to decorrelate and reduce texture features. Local texture descriptors, including rotation-invariant uniform local binary patterns (LBP2riu), local binary patterns (LBP), and binary robust independent elementary features (BRIEF), were combined with machine learning classifiers such as support vector machine (SVM) and K-nearest neighbour (KNN). OCTA datasets from Manchester Royal Eye Hospital and Moorfields Eye Hospital, covering healthy, dry AMD, and wet AMD eyes, were used for evaluation.

Results

The first algorithm achieved a mean area under the receiver operating characteristic curve (AUC) of 1.00±0.00 for distinguishing healthy eyes from wet AMD. The second algorithm showed superior performance in differentiating dry AMD from wet AMD (AUC 0.85±0.02).

Conclusions

The proposed algorithms demonstrate strong potential for rapid and accurate AMD diagnosis in OCTA workflows. By reducing manual image evaluation and associated variability, they may support improved clinical decision-making and patient care.

Для цитирования: Alfahaid Abdullah, Morris Tim, Cootes Tim, Keane Pearse A, Khalid Hagar, Pontikos Nikolas, Alharbi Fatemah, Alalwany Easa, Almars Abdulqader M, Aldweesh Amjad, ALMansour Abdullah G M, Sergouniotis Panagiotis I, Balaskas Konstantinos. Machine Learning-Based Analysis of Optical Coherence Tomography Angiography Images for Age-Related Macular Degeneration.. Biomedicines. 2025. DOI: 10.3390/biomedicines13092152.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.