DOI 10.1016/j.cpcardiol.2024.102674
Basal natriuresis as a predictor of diuretic resistance and clinical evolution in acute heart failure.
Аннотация
BACKGROUND
Some clinical guidelines recommend serial measurement of natriuresis to detect diuretic resistance (DR) in acute heart failure (AHF) patients, but it adds complexity to the management.
OBJECTIVES
To correlate a single measurement of basal natriuresis (BN) on admission with the development of DR and clinical evolution in AHF hospitalized patients.
METHODS
Prospective and multicenter study included AHF hospitalized patients, without shock or creatinine >2.5mg%. Patients received 40mg of intravenous furosemide on admission, then BN was measured, and diuretic treatment was guided by protocol. BN was considered low if <70 meq/L. DR was defined as the need of furosemide >240mg/day, tubular blockade (TB), hypertonic saline solution (HSS) or renal replacement therapy (RRT). In-hospital cardiovascular (CV) mortality, CV mortality and AHF readmissions at 60-day post-discharge were evaluated.
RESULTS
157 patients were included. BN was low in 22%. DR was development in 19% (12.7% furosemide >240mg/day, 8% TB, 4% RRT). Low NB was associated with DR (44% vs 12%; p 0.0001), persistence of congestion (26.5% vs 11.4%; p 0.05), furosemide >240 mg/day (29% vs 8%; p 0.003), higher cumulative furosemide dose at 72 hours (220 vs 160mg; p 0.0001), TB (20.6 vs 4.9%; p 0.008), RRT (11.8 vs 1.6%; p 0.02), worsening of AHF (27% vs 9%; p 0.01), inotropes use (21% vs 7%; p 0.48), respiratory assistance (12% vs 2%; p 0.02) and a higher in-hospital CV mortality (12% vs 4%; p 0.1). No association was demonstrated with post-discharge endpoints.
CONCLUSIONS
In AHF patients, low BN was associated with DR, persistent congestion, need for aggressive decongestion strategies, and worse in-hospital evolution.