MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2012.06.016

Медицинская библиотека · Contraception · 2012

An exploratory, randomized, crossover MRI study of microbicide delivery with the SILCS diaphragm compared to a vaginal applicator.

Pentlicky Sara, Rosen Mark, Coffey Patricia S, Kilbourne-Brook M, Shaunik A, Schreiber Courtney A, Barnhart Kurt

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Microbicide gels studied for HIV prevention often are delivered via a single-use vaginal applicator. Using a contraceptive diaphragm such as the SILCS diaphragm for gel delivery could have advantages, including lower cost and additional pregnancy prevention.

STUDY

DESIGN

We performed an exploratory, nonblinded, randomized, crossover study among healthy, sexually active, nonpregnant women. Using BufferGel, we evaluated three microbicide delivery methods for gel distribution and retention: SILCS single-sided gel delivery, SILCS double-sided gel delivery and a vaginal applicator (without SILCS). Magnetic resonance images were taken at baseline, after gel insertion, and immediately and 6 h after simulated intercourse. Three women completed all gel delivery methods described in this article.

RESULTS

Magnetic resonance imaging analysis indicated similar gel spread in the vagina among all three methods. SILCS single-sided gel application resulted in the most consistent longitudinal coverage; SILCS double-sided gel application was the most consistent in the transverse dimension.

CONCLUSIONS

Gel coverage was similar with all three methods. These results suggest that the SILCS microbicide delivery system is comparable to vaginal applicators for delivery of gel products intravaginally.

Для цитирования: Pentlicky Sara, Rosen Mark, Coffey Patricia S, Kilbourne-Brook M, Shaunik A, Schreiber Courtney A, Barnhart Kurt. An exploratory, randomized, crossover MRI study of microbicide delivery with the SILCS diaphragm compared to a vaginal applicator.. Contraception. 2012. DOI: 10.1016/j.contraception.2012.06.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.