MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hep.30234

Медицинская библиотека · Hepatology (Baltimore, Md.) · 2018

Diagnostic Accuracy of Serum Matrix Metalloproteinase-7 for Biliary Atresia.

Yang Li, Zhou Ying, Xu Pei-Pei, Mourya Reena, Lei Hai-Yan, Cao Guo-Qing, Xiong Xiao-Li, Xu Hui, Duan Xu-Fei, Wang Na, Fei Lin, Chang Xiao-Pan, Zhang Xi, Jiang Meng, Bezerra Jorge A, Tang Shao-Tao

СтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The diagnosis of biliary atresia (BA) remains a clinical challenge because affected infants have signs, symptoms, and serum liver biochemistry that are also seen in those with other causes of neonatal cholestasis (non-BA). However, an early diagnosis and prompt surgical treatment are required to improve clinical outcome. Recently, the relative abundance of serum matrix metalloproteinase-7 (MMP-7) was suggested to have discriminatory features for infants with BA. To test the hypothesis that elevated serum concentration of MMP-7 is highly diagnostic for BA, we determined the normal serum concentration of MMP-7 in healthy control infants, and then in 135 consecutive infants being evaluated for cholestasis. The median concentration for MMP-7 was 2.86 ng/mL (interquartile range, IQR: 1.32-5.32) in normal controls, 11.47 ng/mL (IQR: 8.54-24.55) for non-BA, and 121.1 ng/mL (IQR: 85.42-224.4) for BA (P < 0.0001). The area under the curve of MMP-7 for the diagnosis of BA was 0.9900 with a cutoff value of 52.85 ng/mL; the diagnostic sensitivity and specificity were 98.67% and 95.00%, respectively, with a negative predictive value of 98.28%.

Conclusion

Serum MMP-7 assay has high sensitivity and specificity to differentiate BA from other neonatal cholestasis, and may be a reliable biomarker for BA.

Для цитирования: Yang Li, Zhou Ying, Xu Pei-Pei, Mourya Reena, Lei Hai-Yan, Cao Guo-Qing, Xiong Xiao-Li, Xu Hui, Duan Xu-Fei, Wang Na, Fei Lin, Chang Xiao-Pan, Zhang Xi, Jiang Meng, Bezerra Jorge A, Tang Shao-Tao. Diagnostic Accuracy of Serum Matrix Metalloproteinase-7 for Biliary Atresia.. Hepatology (Baltimore, Md.). 2018. DOI: 10.1002/hep.30234.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.