Journal of nephrology · 2023
Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Balouzet Clara, Michon-Colin Arthur, Dupont Léa, Vidal-Petiot Emmanuelle, Prot-Bertoye Caroline, Baron Stéphanie, Ayari Hamza, Cohen Raphaël, Houillier Pascal, Smadja Corinne, Flamant Martin, Courbebaisse Marie
Аннотация
BACKGROUND: In late 2018, the production of 51Chromium-labelled ethylenediamine tetra-acetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for measuring glomerular filtration rate, was halted. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) has been validated for GFR measurement with a single bolus injection, a procedure not suitable in patients with extracellular compartment hyperhydration. In such cases, a bolus followed by continuous infusion of the tracer is required. The aim of this study was to evaluate whether 99mTc-DTPA with the infusion protocol can replace 51Cr-EDTA for GFR measurement.
METHODS: We conducted a prospective single centre study during February and March 2019. All patients referred for GFR measurement received both radiotracers simultaneously: 51Cr-EDTA and 99mTc-DTPA bolus and continuous infusion were administered concomitantly through the same intravenous route. Over four and a half hours, plasma and urine samples were collected to calculate urinary and plasma clearance.
RESULTS: Twenty-two patients were included (mean age 63.4 ± 17.5 years; 68% men). Mean urinary clearance of 51Cr-EDTA and 99mTc-DTPA was 52.4 ± 22.5 mL/min and 52.8 ± 22.6 mL/min, respectively (p = 0.47), with a mean bias of 0.39 ± 2.50 mL/min, an accuracy within 10% of 100% (95% CI 100; 100) and a Pearson correlation coefficient of 0.994. Mean plasma clearance of 51Cr-EDTA and 99mTc-DTPA was 54.8 ± 20.9 mL/min and 54.4 ± 20.9 mL/min, respectively (p = 0.61), with a mean bias of - 0.43 ± 3.89 mL/min, an accuracy within 10% of 77% (95% CI 59; 91) and a Pearson correlation coefficient of 0.983.
CONCLUSIONS: Urinary and plasma clearance of 99mTc-DTPA can be used with the infusion protocol to measure GFR.
METHODS: We conducted a prospective single centre study during February and March 2019. All patients referred for GFR measurement received both radiotracers simultaneously: 51Cr-EDTA and 99mTc-DTPA bolus and continuous infusion were administered concomitantly through the same intravenous route. Over four and a half hours, plasma and urine samples were collected to calculate urinary and plasma clearance.
RESULTS: Twenty-two patients were included (mean age 63.4 ± 17.5 years; 68% men). Mean urinary clearance of 51Cr-EDTA and 99mTc-DTPA was 52.4 ± 22.5 mL/min and 52.8 ± 22.6 mL/min, respectively (p = 0.47), with a mean bias of 0.39 ± 2.50 mL/min, an accuracy within 10% of 100% (95% CI 100; 100) and a Pearson correlation coefficient of 0.994. Mean plasma clearance of 51Cr-EDTA and 99mTc-DTPA was 54.8 ± 20.9 mL/min and 54.4 ± 20.9 mL/min, respectively (p = 0.61), with a mean bias of - 0.43 ± 3.89 mL/min, an accuracy within 10% of 77% (95% CI 59; 91) and a Pearson correlation coefficient of 0.983.
CONCLUSIONS: Urinary and plasma clearance of 99mTc-DTPA can be used with the infusion protocol to measure GFR.