MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0037-1613684

Медицинская библиотека · American journal of perinatology · 2017

Liver Injury in Hemolysis, Elevated Liver Enzymes, and Low Platelets Syndrome Measured by Diffusion-Weighted Magnetic Resonance Imaging.

Nelson David B, Khan Ambereen, Bailey April, Yokoo Takeshi, Pedrosa Ivan, McIntire Donald D, Cunningham F Gary

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study was to evaluate acute liver injury (ALI) detected by diffusion-weighted magnetic resonance imaging (MRI) and the associated laboratory findings in women with hemolysis, elevated liver enzymes, and low platelet (HELLP) syndrome.

STUDY

DESIGN

This was a retrospective, observational study of women with HELLP syndrome defined by serum aspartate aminotransferase (AST) levels ≥100 U/L and thrombocytopenia with platelets ≤100,000/µL. All women underwent MRI postpartum including diffusion-weighted imaging to estimate the volume of ALI with reconstructed apparent diffusion coefficient (ADC) maps. The ADC map and the volume of ALI were compared with laboratory abnormalities by Spearman's correlation analysis.

RESULTS

From March 2013 through August 2015, 16 women with HELLP syndrome underwent MRI, and of these, 14 (88%) women had areas of increased signal intensity suggestive of ALI. Their median (range) maximum AST level was 262 (140-1,958) IU/L, and at the time of MRI, AST was 103 (36-1,426) IU/L. Both of these AST levels significantly correlated with ADC map as well as the volume of ALI (both p-values <0.001).

CONCLUSION

Women with HELLP syndrome frequently exhibited areas of abnormal diffusion in the liver on diffusion-weighted MRI, suggestive of ALI. The extent of liver injury was significantly correlated with serum AST.

Для цитирования: Nelson David B, Khan Ambereen, Bailey April, Yokoo Takeshi, Pedrosa Ivan, McIntire Donald D, Cunningham F Gary. Liver Injury in Hemolysis, Elevated Liver Enzymes, and Low Platelets Syndrome Measured by Diffusion-Weighted Magnetic Resonance Imaging.. American journal of perinatology. 2017. DOI: 10.1055/s-0037-1613684.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.