MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1081-1206(10)62387-3

Медицинская библиотека · Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology · 2002

A comparison of the efficacy and tolerability of single doses of HFA 134a albuterol and CFC albuterol in mild-to-moderate asthmatic patients.

Langley Stephen J, Sykes Andrew P, Batty Elizabeth P, Masterson Catherine M, Woodcock Ashley

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

After the signing of the Montreal Protocol in 1987, new propellants for use in pressurized metered-dose inhalers that are non-ozone-depleting have been developed.

OBJECTIVE

This study was designed to compare the efficacy and tolerability of single doses of albuterol/HFA 134a with albuterol/CFC and to demonstrate a dose-response among the different doses of both formulations.

METHODS

A single-center, randomized, double-blind, placebo-controlled, cross-over study. Sixty-three adolescent and adult asthmatic patients were randomized to receive at separate treatment visits single doses via a pressurized metered-dose inhaler of either placebo/hydrofluoroalkane (HFA) 134a; 100 microg, 200 microg, or 400 microg albuterol/HFA 134a; 100 microg or 200 microg albuterol/chlorofluorocarbon (CFC). Triplicate measurements of forced expiratory volume in 1 second (FEV1) were made immediately before dosing and 15 minutes, 30 minutes, 1, 2, 3, 4, 5, and 6 hours postdose. The primary efficacy variables were area under the entire 6-hour FEV1 curve, relative to baseline subtracted from the area above baseline (AUC(0-6)) and peak effect (derived from serial FEV1 measurements).

RESULTS

Analysis of AUC(0-6) and peak effect showed that all doses of albuterol had a significantly greater effect than placebo (HFA 134a propellant). Comparisons of the two formulations at 100 microg and 200 microg showed no difference in AUC(0-6) (100 microg, -0.23 Lhr, P = 0.114 and 200 microg -0.08 Lhr, P = 0.590) or in peak effect, percentage of baseline (100 microg, -1.3%, P = 0.354 and 200 microg, 0.17%, P = 0.902). There were no differences seen among formulations in the incidence of adverse events or with any of the other safety parameters, including electrocardiograms, vital signs, clinical laboratory assessments, and asthma exacerbations.

CONCLUSIONS

The study demonstrated comparability in terms of efficacy and safety between albuterol/HFA 134a and albuterol/CFC.

Для цитирования: Langley Stephen J, Sykes Andrew P, Batty Elizabeth P, Masterson Catherine M, Woodcock Ashley. A comparison of the efficacy and tolerability of single doses of HFA 134a albuterol and CFC albuterol in mild-to-moderate asthmatic patients.. Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology. 2002. DOI: 10.1016/s1081-1206(10)62387-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.