MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2015.06.066

Медицинская библиотека · The Annals of thoracic surgery · 2015

Contributory Role of Fluorine 18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Diagnosis and Clinical Management of Infections in Patients Supported With a Continuous-Flow Left Ventricular Assist Device.

Dell'Aquila Angelo Maria, Mastrobuoni Stefano, Alles Sebastian, Wenning Christian, Henryk Welp, Schneider Stefan Rudolf Bertram, Deschka Heinz, Sindermann Jürgen R, Scherer Mirela

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The current study sought to demonstrate the advantages offered by fluorine 18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) in patients supported with continuous-flow left ventricular assist devices (CF-LVADs) in detecting infection and the consequent effect on clinical decisions.

METHODS

Between April 2009 and September 2013, 40 PET examinations were performed in 31 patients (78.1% men; mean age, 51.0 ± 14.9 years) supported with a CF-LVAD. In group A (19 examinations in 14 patients), PET/CT was performed to detect infectious focus in patients without external signs of driveline involvement but with at least two of the following infection signs: recurrent fever, positive blood culture, or elevated infectious indicators. In group B (21 examinations in 17 patients), PET/CT aimed to assess the internal extension of infection in patients with external signs of driveline infection.

RESULTS

In 50% of the cases of the patients in group A, abnormal (18)F-FDG uptake (9 patients) was related to VAD components. Matching the results with the final diagnosis, we reported 9 true-positive, 8 true-negative, no false-negative, and 2 false-positive findings. New information unrelated to VAD was found in 9 patients (50%): pneumonia in 3, colon diverticulitis in 3, sternal dehiscence in 1, paravertebral abscess in 1, and erysipelas in 1. In group B, superficial abnormal (18)F-FDG uptake was found at the piercing site of the driveline in 2 patients, deeper extension of infection along the driveline in 10, initial involvement of the pump housing in 2, and full involvement of the device in 4. These findings contributed to changing the clinical management in 84.2% of group A patients and in 85.7% of group B patients: 16 patients were scheduled for urgent transplantation, 2 underwent surgical revision of the driveline, 7 required prolonged antibiotic therapy, and 3 underwent colonoscopy.

CONCLUSIONS

This single-center experience highlights the diagnostic value of PET/CT in detecting the localization and internal extension of infection to internal VAD components. Moreover, this information notably influences the therapeutic management.

Для цитирования: Dell'Aquila Angelo Maria, Mastrobuoni Stefano, Alles Sebastian, Wenning Christian, Henryk Welp, Schneider Stefan Rudolf Bertram, Deschka Heinz, Sindermann Jürgen R, Scherer Mirela. Contributory Role of Fluorine 18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Diagnosis and Clinical Management of Infections in Patients Supported With a Continuous-Flow Left Ventricular Assist Device.. The Annals of thoracic surgery. 2015. DOI: 10.1016/j.athoracsur.2015.06.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.