MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5334/gh.1322

Медицинская библиотека · Global heart · 2024

Updated 2022 ACC/AHA Guideline Improves Concordance Between TTE and CT in Monitoring Marfan Snydrome and Related Disorders, but Relevant Measurement Differences Remain Frequent.

Kolck Johannes, Trippel Tobias Daniel, Philipp Karla, Gehle Petra, Geisel Dominik, Beetz Nick Lasse

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patients diagnosed with Marfan syndrome or a related syndrome require frequent aorta monitoring using imaging techniques like transthoracic echocardiography (TTE) and computed tomography (CT). Accurate aortic measurement is crucial, as even slight enlargement (>2 mm) often necessitates surgical intervention. The 2022 ACC/AHA guideline for Aortic Disease Diagnosis and Management includes updated imaging recommendations. We aimed to compare these with the 2010 guideline.

METHODS

This retrospective study involved 137 patients with Marfan syndrome or a related disorder, undergoing TTE and ECG-triggered CT. Aortic diameter measurements were taken based on the old 2010 guideline (TTE: inner edge to inner edge, CT: external diameter) and the new 2022 guideline (TTE: leading edge to leading edge, CT: internal diameter). Bland-Altman plots compared measurement differences.

RESULTS

Using the 2022 guideline significantly reduced differences outside the clinical agreement limit from 49% to 26% for the aortic sinus and from 41% to 29% for the ascending aorta. Mean differences were -0.30 mm for the aortic sinus and +1.12 mm for the ascending aorta using the 2022 guideline, compared to -2.66 mm and +1.21 mm using the 2010 guideline.

CONCLUSION

This study demonstrates for the first time that the 2022 ACC/AHA guideline improves concordance between ECG-triggered CT and TTE measurements in Marfan syndrome patients, crucial for preventing life-threatening aortic complications. However, the frequency of differences >2 mm remains high.

CLINICAL RELEVANCE/APPLICATION: Accurate aortic diameter measurement is vital for patients at risk of fatal aortic complications. While the 2022 guideline enhances concordance between imaging modalities, frequent differences >2 mm persist, potentially impacting decisions on aortic repair. The risk of repeat radiation exposure from ECG-triggered CT, considered the 'gold standard', continues to be justified.

Для цитирования: Kolck Johannes, Trippel Tobias Daniel, Philipp Karla, Gehle Petra, Geisel Dominik, Beetz Nick Lasse. Updated 2022 ACC/AHA Guideline Improves Concordance Between TTE and CT in Monitoring Marfan Snydrome and Related Disorders, but Relevant Measurement Differences Remain Frequent.. Global heart. 2024. DOI: 10.5334/gh.1322.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.