MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2013/452857

Медицинская библиотека · BioMed research international · 2013

Near-infrared spectroscopy of the urinary bladder during voiding in men with lower urinary tract symptoms: a preliminary study.

Farag Fawzy F, Meletiadis Joseph, Saleem Mohamad D, Feitz Wout F, Heesakkers John P

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the difference in response of NIRS of the bladder during voiding between men with and without BOO.LUTS.

METHODS

A prospective, case series, study included 36 men with LUTS. Patients completed the IPSS questionnaire; prostate volumes were measured sonographically. Patients underwent pressure flow study (PFS) with simultaneous NIRS of the bladder. Amplitudes of HHb, O2Hb, and Hbsum were calculated at Qmax, relative to baseline. Patients were urodynamically classified as obstructed and unobstructed. Recursive partition analysis (RPA) was performed to reclassify patients using NIRS amplitudes, followed by combined data of NIRS amplitudes, prostate volume, IPSS, and Qmax to determine the best predictor(s) of BOO.

RESULTS

PFS classified 28 patients as obstructed and 8 as unobstructed. The median HHb amplitude was significantly higher in obstructed group. RPA of NIRS amplitudes correctly reclassified 89% of patients [AUC: 0.91]. RPA of the combined IPSS, prostate volume, PVR, and Qmax correctly reclassified 72% of patients [AUC: 0.84]. When NIRS amplitudes were added to this combination, RPA revealed a significantly (P < 0.01) higher rate of correct reclassification in 89% of patients with 89.3% sensitivity and 88% specificity for obstruction [AUC: 0.96].

CONCLUSION

NIRS data can be of diagnostic value for BOO in men with LUTS.

Для цитирования: Farag Fawzy F, Meletiadis Joseph, Saleem Mohamad D, Feitz Wout F, Heesakkers John P. Near-infrared spectroscopy of the urinary bladder during voiding in men with lower urinary tract symptoms: a preliminary study.. BioMed research international. 2013. DOI: 10.1155/2013/452857.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.