MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2020.04.005

Медицинская библиотека · American heart journal · 2020

Evaluation of safety and efficacy of coronary intravascular lithotripsy for treatment of severely calcified coronary stenoses: Design and rationale for the Disrupt CAD III trial.

Kereiakes Dean J, Hill Jonathan M, Ben-Yehuda Ori, Maehara Akiko, Alexander Beaux, Stone Gregg W

Протокол клинического исследованияСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Coronary calcification limits optimal stent expansion and apposition and worsens safety and effectiveness outcomes of percutaneous coronary intervention (PCI). Current ablative technologies that modify calcium to optimize stent deployment are limited by guidewire bias and periprocedural complications related to atheroembolization, coronary dissection, and perforation. Intravascular lithotripsy (IVL) delivers pulsatile ultrasonic pressure waves through a fluid-filled balloon into the vessel wall to modify calcium and enhance vessel compliance, reduce fibroelastic recoil, and decrease the need for high-pressure balloon (barotrauma) inflations. IVL has been used in peripheral arteries as stand-alone revascularization or as an adjunct to optimize stent deployment. STUDY DESIGN AND

OBJECTIVES

Disrupt CAD III (clinicaltrials.gov identifier: NCT03595176) is a prospective, multicenter, single-arm study designed to assess safety and efficacy of the Shockwave coronary IVL catheter to optimize coronary stent deployment in patients with de novo calcified coronary stenoses. The primary safety end point is freedom from major adverse cardiovascular events (composite of cardiac death, myocardial infarction, and target vessel revascularization) at 30 days compared to a prespecified performance goal. The primary effectiveness end point is procedural success without in-hospital major adverse cardiovascular events. Enrollment will complete early in 2020 with clinical follow-up ongoing for 2 years.

CONCLUSION

Disrupt CAD III will evaluate the safety and effectiveness of the Shockwave coronary IVL catheter to optimize coronary stent deployment in patients with calcified coronary stenoses.

Для цитирования: Kereiakes Dean J, Hill Jonathan M, Ben-Yehuda Ori, Maehara Akiko, Alexander Beaux, Stone Gregg W. Evaluation of safety and efficacy of coronary intravascular lithotripsy for treatment of severely calcified coronary stenoses: Design and rationale for the Disrupt CAD III trial.. American heart journal. 2020. DOI: 10.1016/j.ahj.2020.04.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.