MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13312-010-0020-7

Медицинская библиотека · Indian pediatrics · 2009

Light emitting diodes versus compact fluorescent tubes for phototherapy in neonatal jaundice: a multi center randomized controlled trial.

Kumar Praveen, Murki Srinivas, Malik G K, Chawla Deepak, Deorari Ashok K, Karthi N, Subramanian Sreeram, Sravanthi Jonnala, Gaddam Pramod, Singh S N

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To evaluate whether light-emitting diode (LED) phototherapy is as efficacious as compact fluorescent tube (CFT) phototherapy for the treatment of non-hemolytic jaundice in healthy term and late preterm neonates.

STUDY

DESIGN

Multi centre open label randomized controlled trial.

SETTING

Four tertiary care neonatal units.

SUBJECTS: Healthy term and late preterm neonates with non-hemolytic jaundice.

INTERVENTION: Single-surface LED or CFT phototherapy.

PRIMARY OUTCOME VARIABLE: Duration of phototherapy.

RESULTS

A total of 272 neonates were randomized to receive LED (n=142) or CFT (n=130) phototherapy. The baseline demographic and biochemical variables were similar in the two groups. The median duration of phototherapy (IQR) in the two groups was comparable (26 (22-36) h vs. 25(22-36) h; P=0.44). At any time point, a similar proportion of neonates were under phototherapy in the two groups (log-rank test, P=0.38). The rate of fall of serum total bilirubin (STB) during phototherapy and the incidence of failure of phototherapy were also not different. An equal proportion of neonates had a rebound increase in STB needing restarting of phototherapy. Side effects were rare, comparable in the two groups and included hypothermia, hyperthermia, rash, skin darkening and dehydration.

CONCLUSIONS

LED and CFT phototherapy units were equally efficacious in the management of non-hemolytic hyperbilirubinemia in healthy term and late preterm neonates.

Для цитирования: Kumar Praveen, Murki Srinivas, Malik G K, Chawla Deepak, Deorari Ashok K, Karthi N, Subramanian Sreeram, Sravanthi Jonnala, Gaddam Pramod, Singh S N. Light emitting diodes versus compact fluorescent tubes for phototherapy in neonatal jaundice: a multi center randomized controlled trial.. Indian pediatrics. 2009. DOI: 10.1007/s13312-010-0020-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.