MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2009.28.12.1645

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2009

Satisfactory visualization rates of standard cardiac views at 18 to 22 weeks' gestation using spatiotemporal image correlation.

Cohen Leeber, Mangers Kristie, Grobman William A, Platt Lawrence D

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to determine the frequency with which 3 standard screening views of the fetal heart (4-chamber, left ventricular outflow tract [LVOT], and right ventricular outflow tract [RVOT]) can be obtained satisfactorily with the spatiotemporal image correlation (STIC) technique.

METHODS

A prospective study of 111 patients undergoing anatomic surveys at 18 to 22 weeks was performed. Two ultrasound machines with fetal cardiac settings were used. The best volume set that could be obtained from each patient during a 45-minute examination was graded by 2 sonologists with regard to whether the 4-chamber, LVOT, and RVOT images were satisfactory for screening.

RESULTS

All 3 views were judged satisfactory for screening in most patients: 1 sonologist graded the views as satisfactory in 70% of the patients, whereas the other found the views to be satisfactory in 83%. The position of the placenta did not alter the probability of achieving a satisfactory view, but a fetus in the spine anterior position was associated with a significantly lower probability that the views were regarded as satisfactory for screening (odds ratio, 0.28; 95% confidence interval, 0.09-0.70; P < .05).

CONCLUSIONS

This study suggests that STIC may assist with screening for cardiac anomalies at 18 to 22 weeks' gestation.

Для цитирования: Cohen Leeber, Mangers Kristie, Grobman William A, Platt Lawrence D. Satisfactory visualization rates of standard cardiac views at 18 to 22 weeks' gestation using spatiotemporal image correlation.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2009. DOI: 10.7863/jum.2009.28.12.1645.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.