MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12884-023-05652-z

Медицинская библиотека · BMC pregnancy and childbirth · 2023

Clinical practice guidelines for the antenatal management of dichorionic diamniotic twin pregnancies: a systematic review.

O'Connor Caroline, O'Connor Emily, Leitao Sara, Barrett Shauna, O'Donoghue Keelin

Систематический обзорСтатьяПеревод в очереди

Аннотация

OBJECTIVE

This review aimed to identify guidelines with recommendations applicable to the antenatal management of dichorionic diamniotic twin pregnancies within high-income countries, appraise their methodological quality, and discuss the similarities and variability across guidelines.

METHOD: A systematic literature review of electronic databases was performed. Manual searches of guideline repositories and websites of professional organisations were performed to identify additional guidelines. The protocol for this systematic review was registered on PROSPERO (CRD42021248586, 25 June 2021). AGREE II and AGREE-REX tools were applied to assess the quality of eligible guidelines. A narrative and thematic synthesis described and compared the guidelines and their recommendations.

RESULTS

Twenty-four guidelines were included, from which 483 recommendations were identified across 4 international organisations and 12 countries. Guidelines addressed eight themes and recommendations were classified accordingly: chorionicity and dating (103 recommendations), fetal growth (105 recommendations), termination of pregnancy (12 recommendations), fetal death (13 recommendations), fetal anomalies (65 recommendations), antenatal care (65 recommendations), preterm labour (56 recommendations) and birth (54 recommendations). Guidelines showed significant variability in recommendations, with conflicting recommendations regarding non-invasive preterm testing, definitions surrounding selective fetal growth restriction, screening for preterm labour and the timing of birth. Guidelines lacked a focus on standard antenatal management of DCDA twins, management of discordant fetal anomaly and single fetal demise.

CONCLUSIONS

Specific guidance for dichorionic diamniotic twins is overall indistinct and access to guidance regarding the antenatal management of these pregnancies is currently difficult. Management of discordant fetal anomaly or single fetal demise needs greater consideration.

Для цитирования: O'Connor Caroline, O'Connor Emily, Leitao Sara, Barrett Shauna, O'Donoghue Keelin. Clinical practice guidelines for the antenatal management of dichorionic diamniotic twin pregnancies: a systematic review.. BMC pregnancy and childbirth. 2023. DOI: 10.1186/s12884-023-05652-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.