MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ijgo.15375

Медицинская библиотека · International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2024

Timing of cesarean delivery for fetal heart rate abnormalities in hypertensive pregnancies induced with oral misoprostol or Foley catheter: Secondary analysis of a randomized clinical trial.

Londero Ambrogio P, Fichera Anna, Orabona Rossana, Cagnacci Angelo, Prefumo Federico

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The study aims to assess how oral misoprostol for cervical ripening affects the time of cesarean delivery (CD) for fetal heart rate (FHR) abnormalities in pre-eclampsia patients. Secondary goals include determining the role of uterine hyperstimulation, comparing misoprostol with Foley catheter, and identifying risk factors for FHR abnormalities associated with CD.

METHODS

A previously published randomized clinical trial was subjected to a secondary analysis (NCT01801410). We conducted a time-dependent analysis, stratifying the population based on the final mode of induction used (low-dose oral misoprostol vs Foley catheter).

RESULTS

There was no CD for FHR abnormalities within 2 h of starting misoprostol. At 5 h, the cumulative incidence of CD for FHR abnormalities in the misoprostol group was 2.10%, while it was 1.00% in the Foley group (P = 0.565). After 25 h, the CD risk for FHR abnormalities remained constant in both groups at 21.00% (95% confidence interval [CI] 15.00%-28.00%). Within 5 h of misoprostol induction, the risk of uterine hyperstimulation was similar in both groups (0.33% in misoprostol vs 0.34% in Foley group, P = 0.161). The risk of CD for FHR abnormalities was unaffected by newborn weight centiles.

CONCLUSION

There was no significant difference in CD risk for FHR abnormalities between misoprostol and Foley catheter induction. Nonetheless, the cumulative incidence of CD for FHR abnormalities increased faster in the misoprostol group, indicating that FHR monitoring timing should be tailored to the induction method.

Для цитирования: Londero Ambrogio P, Fichera Anna, Orabona Rossana, Cagnacci Angelo, Prefumo Federico. Timing of cesarean delivery for fetal heart rate abnormalities in hypertensive pregnancies induced with oral misoprostol or Foley catheter: Secondary analysis of a randomized clinical trial.. International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics. 2024. DOI: 10.1002/ijgo.15375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.