Vinyl Chloride Monomer (VCM) is an industrial contaminant and carcinogen classified in IARC group 1. Chronic exposure to VCM may lead to serious health problems. Thiodiglycolic acid (TDGA) acts as a biomarker for exposure to VCM; hence, its quantitative estimation in urine provides precise information about exposure level. In this study, the authors propose a newly developed colorimetric assay based on metal-organic framework (MOFs), specifically MIL-100(Fe), acting as a nanozyme. In particular, it shows strong peroxidase-like activity; as such, it generates blue color in response to hydrogen peroxide (H2O2) and 3,3',5,5'-Tetramethylbenzidine (TMB). The optimum reaction conditions were determined via response surface methodology (RSM) to maximize the assay's sensitivity and performance. Under optimal conditions, the method achieved a limit of detection (LOD) of 2.48 ppm and a linear range of 1 to 200 ppm. The assay demonstrated high accuracy and precision in spiked urine samples, with recoveries ranging from 93.74% to 96.81% relative to theoretical values. The proposed test provides ease of performance, scalability, and cost efficiency as well as acceptable specificity and sensitivity; hence, it would be an ideal method for estimating exposure levels to VCM in human workers. The developed colorimetric assay, in contrast to present gold standard techniques such as GC-MS, is transportable, and the analysis can be done either by an inexpensive UV-Vis spectrophotometer or a smartphone. The whole process can be accomplished in less than 15 min, which makes it amenable to site-specific biologic monitoring in the petrochemical industry. This can be especially relevant in developing nations. The proposed method bridges an important gap for biological monitoring in occupational health surveillance where a need for immediate, cost-effective, and transportable methods for testing TDGA exists.

Для цитирования: Kalkenari Fatemeh Azizi, Khaloo Shokooh Sadat, Dehghan Somayeh Farhang, Hajighasemkhan Alireza. Evaluation of thiodiglycolic acid as a urinary biomarker for exposure to vinyl chloride monomer: Development and analytical validation of a colorimetric method based on metal-organic frameworks.. Journal of occupational and environmental hygiene. 2026. DOI: 10.1080/15459624.2026.2703489.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.