MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2196/87368

Медицинская библиотека · JMIR medical informatics · 2026

Improving Radiology Report Error Detection Using a Multipass Large Language Model: Framework Development and Validation.

Kim Songsoo, Lee Seungtae, Lee See Young, Kim Joonho, Kan Keechan, Lee Hyunji, Yoon Dukyong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Large language model (LLM) proofreaders for radiology reports generate many false positives (FPs) due to the low prevalence of errors.

OBJECTIVE

This study aimed to determine whether an optimized LLM framework could improve both precision and cost-efficiency without compromising error detection capability.

METHODS

In this retrospective study, 1000 radiology reports (radiography, ultrasonography, computed tomography, and magnetic resonance imaging; 250 each) were sampled from the Medical Information Mart for Intensive Care III database. Two public chest radiography corpora (CheXpert and Open-i) served as external test sets. Three LLM frameworks were evaluated: single-prompt detector (framework 1); report extractor plus single-prompt detector (framework 2); and extractor, detector, and FP verifier (framework 3). Precision for each framework was assessed using positive predictive value (PPV) and detected errors per 1000 reports. Overall efficiency was estimated using model inference costs and reviewer labor costs.

RESULTS

PPV increased from 0.063 (95% CI 0.036-0.101) in framework 1 to 0.079 (95% CI 0.049-0.118) in framework 2 and 0.159 (95% CI 0.090-0.252) in framework 3 (P<.001). Despite improved PPV, detected errors remained stable (detected errors per 1000 reports: 12-14). Human review burden decreased from 192 to 88 reports. Framework 3 also reduced model inference costs to US $5.57 per 1000 reports (vs US $9.72 and US $6.85 for frameworks 1 and 2; 42.6% and 18.5% reductions, respectively). External validation confirmed similar improvements. Qualitative analysis revealed that remaining FPs in framework 3 were largely confined to cases requiring deep clinical context (clinically equivalent rephrasing: 53%; unsupported discrepancy assertions: 43%). By eliminating structural FPs (eg, section mismatches and lexical errors: 0%), the framework effectively shifted the quality assurance burden to a smaller set of ambiguous cases, enabling a targeted human-in-the-loop workflow.

CONCLUSIONS

The multipass LLM improved the precision and cost-efficiency of radiology report error detection in real-world, low-error prevalence settings. The framework demonstrates the feasibility of synergistic artificial intelligence-radiologist collaboration and provides a cost-effective and scalable approach to artificial intelligence-assisted quality assurance in both radiological practice and research.

Для цитирования: Kim Songsoo, Lee Seungtae, Lee See Young, Kim Joonho, Kan Keechan, Lee Hyunji, Yoon Dukyong. Improving Radiology Report Error Detection Using a Multipass Large Language Model: Framework Development and Validation.. JMIR medical informatics. 2026. DOI: 10.2196/87368.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.