MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-017-0836-0

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2017

Antegrade intramedullary Kirschner-wire fixation of displaced metacarpal shaft fractures.

van Bussel E M, Houwert R M, Kootstra T J M, van Heijl M, Van der Velde D, Wittich Ph, Keizer J

СтатьяПеревод в очереди

Аннотация

PURPOSE: The objective of this study was to analyze complications and patient-related functional outcome after antegrade intramedullary Kirschner-wire fixation of metacarpal shaft fractures.

METHODS

All consecutive patients treated from January 2010 until December 2015 were retrospectively analyzed using patient logs and radiographic images. Indications for operative fixation were angulation > 40°, shortening > 2 mm, or rotational deficit. Complications were registered from the patient logs. Functional outcome was assessed with the Patient-rated wrist/hand evaluation (PRWHE) and Disabilities of the Arm, Shoulder, and Hand score (DASH) questionnaire both ranging from 1 to 100 after a minimum follow-up of 6 months.

RESULTS

During the study period, 34 fractures of 27 patients could be included. Mean outpatient follow-up was 11 weeks (range 4-24 weeks). The mean interval for functional assessment was 30 months (range 8-62 months) and 19 patients (70%) responded to the questionnaires. During outpatient follow-up, all fractures proceeded to union with no signs of secondary fracture dislocation or implant migration. One re-fracture after a new adequate trauma was seen and one patient underwent tenolysis due to persistent pain and impaired function. In 26 cases (81%), the K-wires were removed of which 23 (68%) were planned removals. Functional outcome was excellent with mean PRWHE and DASH scores of 7 and 5 points, respectively.

CONCLUSIONS

If surgical treatment for metacarpal shaft fractures is considered, we recommend antegrade intramedullary K-wire fixation. This technique results in low complication rates and excellent functional outcome.

Для цитирования: van Bussel E M, Houwert R M, Kootstra T J M, van Heijl M, Van der Velde D, Wittich Ph, Keizer J. Antegrade intramedullary Kirschner-wire fixation of displaced metacarpal shaft fractures.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2017. DOI: 10.1007/s00068-017-0836-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.