MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/neurintsurg-2017-013384

Медицинская библиотека · Journal of neurointerventional surgery · 2017

Recurrence risk factors in detachable balloon embolization of traumatic direct carotid cavernous fistulas in 188 patients.

Gao Bu-Lang, Wang Zi-Liang, Li Tian-Xiao, Xu Bin

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the effects of detachable balloons in embolizing traumatic carotid cavernous fistulas (TCCFs) and the risk factors for recurrence after balloon embolization.

MATERIALS AND

METHODS

188 patients with TCCFs were enrolled, and clinical, treatment, and follow-up data were analyzed for possible risk factors for recurrence after embolization.

RESULTS

Among 188 patients, 182 (96.8%) had successful balloon embolization; 6 patients failed. One balloon was used in 94 cases and multiple (two or more) balloons were used in 62 patients. 26 patients had occlusion of the parent artery whereas the remainder had parent artery preservation. Periprocedural complications occurred in 3 patients (1.6%) including cerebral embolism in 1 and abducent nerve paralysis in the other 2. Immediately following embolization, headache appeared in 92 patients and was relieved after 3-5 days with medications. A total of 165 patients (87.8%) had follow-up (6 months to 16 years, mean 5 years). 23 (13.9%) patients with internal carotid artery preservation had recurrence 1-33 days (mean 11 days) after the first embolization and were retreated to complete occlusion. Factors affecting recurrence were multiple balloons and residual fistula (p<0.05). Logistic regression confirmed the independent factors affecting recurrence were multiple balloons (≥2 balloons, OR 7.80, 95% CI 2.28 to 26.73; p=0.001) and residual fistula immediately following embolization (OR 10.46, 95% CI 2.99 to 36.5; p=0.000).

CONCLUSION

The recurrence rate is high in the first month after embolization with detachable balloons, and multiple balloons and residual fistula are two independent factors affecting recurrence following balloon embolization.

Для цитирования: Gao Bu-Lang, Wang Zi-Liang, Li Tian-Xiao, Xu Bin. Recurrence risk factors in detachable balloon embolization of traumatic direct carotid cavernous fistulas in 188 patients.. Journal of neurointerventional surgery. 2017. DOI: 10.1136/neurintsurg-2017-013384.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.