Furosemide: Would it help to improve the lungs as evaluated by sonography and compliance during aortic coarctation surgery.

Mohammed Ahmed Kareem, Madkour Mai A, Hassanien Hossam M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We evaluated furosemide on attenuating lung injury and/or edema during coarctation repair surgery. We evaluated dynamic lung compliance. We measured the degree of lung edema by means of lung ultrasound (LUS). We recorded the (PaO2/FiO2ratio) as an indicator for oxygenation.

MATERIALS AND

METHODS

A study was conducted on 56 patients. Patients were divided into two groups: control group (Group C) which did not receive furosemide and furosemide group (Group F) at a dose of 1 mg/kg at induction of anesthesia. Dynamic lung compliance was calculated at induction (Cdyn 1) and at the end of the surgery (Cdyn 2). The (PaO2/FiO2ratio) was calculated at start and end of surgery as (PF 1) and (PF 2), respectively. LUS was performed after induction (LUS 1) and at the end of the surgery. LUS 2 using the 12 regions method plotting the results on scale from 0 to 36. Mechanical ventilation days were recorded.

RESULTS

Administering furosemide attenuated the lung injury/edema and other pulmonary complications. Furosemide administration improved the dynamic lung compliance in the F Group compared to the C Group. Furthermore, it increased the (PaO2/FiO2ratio) in the F Group compared to the C Group. LUS scale values were lower in the F Group compared to the C Group. There was also less postoperative mechanical ventilation days.

CONCLUSIONS

The use of furosemide was accompanied by improved lung injury/edema profile as indicated by a much less drop in dynamic lung compliance, better oxygenation, a more favorable LUS scale with less parenchymal lung affection.

Для цитирования: Mohammed Ahmed Kareem, Madkour Mai A, Hassanien Hossam M. Furosemide: Would it help to improve the lungs as evaluated by sonography and compliance during aortic coarctation surgery.. Annals of cardiac anaesthesia. 2019. DOI: 10.4103/aca.aca_55_18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.