MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7189/jogh.14.04115

Медицинская библиотека · Journal of global health · 2024

Post-natal gestational age assessment using targeted metabolites of neonatal heel prick and umbilical cord blood: A GARBH-Ini cohort study from North India.

Ramasamy Thirunavukkarasu, Varughese Bijo, Singh Mukesh, Tailor Pragya, Rao Archana, Misra Sumit, Sharma Nikhil, Desiraju Koundiya, Thiruvengadam Ramachandran, Wadhwa Nitya, GARBH-Ini Study Group, Kapoor Seema, Bhatnagar Shinjini, Kshetrapal Pallavi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Accurate assessment of gestational age (GA) and identification of preterm birth (PTB) at delivery is essential to guide appropriate post-natal clinical care. Undoubtedly, dating ultrasound sonography (USG) is the gold standard to ascertain GA, but is not accessible to the majority of pregnant women in low- and middle-income countries (LMICs), particularly in rural areas and small secondary care hospitals. Conventional methods of post-natal GA assessment are not reliable at delivery and are further compounded by a lack of trained personnel to conduct them. We aimed to develop a population-specific GA model using integrated clinical and biochemical variables measured at delivery.

METHODS

We acquired metabolic profiles on paired neonatal heel prick (nHP) and umbilical cord blood (uCB) dried blood spot (DBS) samples (n = 1278). The master data set consists of 31 predictors from nHP and 24 from uCB after feature selection. These selected predictors including biochemical analytes, birth weight, and placental weight were considered for the development of population-specific GA estimation and birth outcome classification models using eXtreme Gradient Boosting (XGBoost) algorithm.

RESULTS

The nHP and uCB full model revealed root mean square error (RMSE) of 1.14 (95% confidence interval (CI) = 0.82-1.18) and of 1.26 (95% CI = 0.88-1.32) to estimate the GA as compared to actual GA, respectively. In addition, these models correctly estimated 87.9 to 92.5% of the infants within ±2 weeks of the actual GA. The classification models also performed as the best fit to discriminate the PTB from term birth (TB) infants with an area under curve (AUC) of 0.89 (95% CI = 0.84-0.94) for nHP and an AUC of 0.89 (95% CI = 0.85-0.95) for uCB.

CONCLUSION

The biochemical analytes along with clinical variables in the nHP and uCB data sets provide higher accuracy in predicting GA. These models also performed as the best fit to identify PTB infants at delivery.

Для цитирования: Ramasamy Thirunavukkarasu, Varughese Bijo, Singh Mukesh, Tailor Pragya, Rao Archana, Misra Sumit, Sharma Nikhil, Desiraju Koundiya, Thiruvengadam Ramachandran, Wadhwa Nitya, GARBH-Ini Study Group, Kapoor Seema, Bhatnagar Shinjini, Kshetrapal Pallavi. Post-natal gestational age assessment using targeted metabolites of neonatal heel prick and umbilical cord blood: A GARBH-Ini cohort study from North India.. Journal of global health. 2024. DOI: 10.7189/jogh.14.04115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.