MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ebiom.2020.102924

Медицинская библиотека · EBioMedicine · 2020

Development and validation of a novel scoring system developed from a nomogram to identify malignant pleural effusion.

Wang Sufei, Tian Shan, Li Yuan, Zhan Na, Guo Yingyun, Liu Yu, Xu Juanjuan, Ma Yanling, Zhang Shujing, Song Siwei, Geng Wei, Xia Hui, Ma Pei, Wang Xuan, Liao Tingting, Duan Yanran, Jin Yang, Dong Weiguo

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

This study aimed to establish and validate a novel scoring system based on a nomogram for the differential diagnosis of malignant pleural effusion (MPE) and benign pleural effusion (BPE).

METHODS

Patients with PE and confirmed aetiology who underwent diagnostic thoracentesis were included in this study. One retrospective set (N = 1261) was used to develop and internally validate the predictive model. The clinical, radiological and laboratory features were collected and subjected to logistic regression analyses. The primary predictive model was displayed as a nomogram and then modified into a novel scoring system, which was externally validated in an independent set (N = 172).

FINDINGS: The novel scoring system was composed of fever (3 points), erythrocyte sedimentation rate (4 points), effusion adenosine deaminase (7 points), serum carcinoembryonic antigen (CEA) (4 points), effusion CEA (10 points) and effusion/serum CEA (8 points). With a cutoff value of 15 points, the area under the curve, specificity and sensitivity for identifying MPE were 0.913, 89.10%, and 82.63%, respectively, in the training set, 0.922, 93.48%, 81.51%, respectively, in the internal validation set and 0.912, 87.61%, 81.36%, respectively, in the external validation set. Moreover, this scoring system was exclusively applied to distinguish lung cancer with PE from tuberculous pleurisy and showed a favourable diagnostic performance in the training and validation sets.

INTERPRETATION: This novel scoring system was developed from a retrospective study and externally validated in an independent set based on six easily accessible clinical variables, and it exhibited good diagnostic performance for identifying MPE.

FUNDING: NFSC grants (no. 81572942, no. 81800094).

Для цитирования: Wang Sufei, Tian Shan, Li Yuan, Zhan Na, Guo Yingyun, Liu Yu, Xu Juanjuan, Ma Yanling, Zhang Shujing, Song Siwei, Geng Wei, Xia Hui, Ma Pei, Wang Xuan, Liao Tingting, Duan Yanran, Jin Yang, Dong Weiguo. Development and validation of a novel scoring system developed from a nomogram to identify malignant pleural effusion.. EBioMedicine. 2020. DOI: 10.1016/j.ebiom.2020.102924.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.